DISTRIBUTION ADJUSTMENT
Distribution adjustment must be done in compliance with:
- the kind of seed that has to be distributed;
- the longitudinal distance between one seed and another.
Kind of seed to be distributed:
Identify the diameter of the holes of the seed disk in Table 4,
according to the type of seed to distribute.
For special requirements make a specific order.
The values shown on the table are approximate. The definite
choice of seed plates is completely up to the user. Complaints
for imprecise sowing due to utilization of improper seed plates
will not be accepted.
Longitudinal distance between one seed and another:
The longitudinal seeding distance is determined by the number
of holes on the seed plate, by the number of teeth and position of
the gears on the wheel which transmits the motion to the gearbox,
and by how the gears are combined in the gearbox.
On the cover of the gearbox there is a table for adjusting the
seeding distance and a table that shows the drive fitted on the
gear drive wheel.
Table 4
(*) Special for beans.
(**) The seed distributor cover should be replaced by a special one suitable for small seeds.
For special requirements make a specific order. The values shown on the table are approximate. The definite choice of seed plates is
completely up to the user. Complaints for imprecise sowing due to utilization of improper seed plates will not be accepted.
cod. G19502561
USE AND MAINTENANCE
1) From the Seed Investment Table:
Depending on both the row distance of the planter and the
selected seed investment per hectare, calculate the longitudinal
seed planting distance by using Table 3 (Seed Investment Table).
Example:
- Seeding row distance 75 cm;
- number of seeds to be distributed per hectare: 72.000.
According to the "Seed investment Table", the longitudinal
distance between one seed and another is 18,50 cm.
For row distances differing from those listed in the table, apply
the following directions:
Longitudinal seeding distance =
Example:
- Ha = 10000 m
- Row distance = 0,90 m;
- No. of seeds to be distributed for hectare = 70.000
Longitudinal seeding dist =
(cm)
2) About the Seed Planter:
Verifiy which couple of pinions (Wheel) is to be found (C-D ill. no.
25) in the seed planter;
Fig 25
g
(
Ha
Row distance X 100
No. of seeds/ha
2
;
(
)
2
10000m
0,90
70000
C
D
ENGLISH
)
X 100 = 15,87 cm