Err 2.3 Power supply to the motor too great
This malfunction must be corrected by the bike itself.
If this malfunction occurs, the bike automatically turns
the motor off to prevent damage. If this message
occurs frequently, we advise you to go to your dealer
so that he can fix the malfunction. (Photo 37)
Err 2.4
Motor sensors do not function
correctly
Check if the motor cable is attached properly. Follow
the instructions under "removing the front wheel" to
open the connector box on the front fork. Check if the
connection of the motor cable is still firmly attached in
the connector box. If the malfunction isn't solved, you
must contact your dealer. (Photo 38)
Err 2.5
No or incorrect speed pulse from
motor
Your display doesn't show a speed whereas the other
functions of the display work correctly. Go to your
dealer to have this malfunction fixed. (Photo 39)
Err 2.7
Bike not registered
Your dealer has not registered the bike correctly with
Gazelle. Electric assistance will therefore cease after 40
km. Return to your dealer and ask him to register your
bike correctly.
Err 3.1
Pedal power measurement error
An error has occurred within the module that has to
translate the delivered pedal power and the requested
degree of assistance into the extent of motor support.
If this error message is shown, the system was not able
to recalibrate itself. Go to your dealer to have this
malfunction fixed. (Photo 40)