2. Parts

2.1 Delivery check

Check that the equipment is complete in accordance with the
packing list, and undamaged.
Packing list
• Facepiece with breathing hose
• Control valve threaded onto a belt
• Sealing cover
• Pre-filter holder
• Flow meter
• User instructions

2.2 Accessories / Spare parts

Fig. 1.
Item Part
1. Breathing hose
1a. Hose clip
2. SR 90 S/M facepiece with hose
3. SR 90 M/L facepiece with hose
4. Belt
4. Belt PVC
5. Control valve SR 347
6. Flow meter
7. Silencer
8. Gasfilter (SR 217 A1, SR 218 A2,
SR 315 ABE1, SR 294 A2B2E1, SR 297 ABEK1,
SR 298 A2AX, SR 316 K1, SR 295 K2,
SR 299-2 ABEK-Hg-P3R)
9. Particle filter SR 510 P3 R
10. Pre-filter
11. Steel net disc
12. Sealing cover
Service kit (13a, b, set of membrane)
13a. Head harness
13b. Pre-filter holder
Set of membrane
Set of membrane (14a, b, c)
14a. Inhalation membrane 1x
14b. Exhalation membrane 2x
14c. Exhalation valve cover 2x
15.
ID-tag
16.
SR 358 Plastic tube 5/10/15/20/25/30 m
SR 359 Rubber tube 5/10/15/20/25/30 m
SR 360 Spiral tube 2/4/6/8 m
17.
Cleaning wipes. Box of 50
Compressed air filter SR 99-1. Fig. 13
3. Use
3.1 Installation
3.1.1 Filters
See the user instructions for the filters.
3.2 Functional check
• Check that the mask is complete, correctly assembled,
thoroughly cleaned and undamaged.
• Check particularly carefully the inhalation and exhalation
membranes and their seats. The membranes are consumables
and must be replaced if there are any signs of damage or ageing.
• Check the condition of the head harness. The head harness
is a consumable item and should be replaced if there are any
signs of wear or reduced elasticity.
• On every occasion before using the equipment:
Check on the rated capacity of the compressed air
o
system.
Check the maximum number of users permitted.
o
Check the number of users already connected.
o
Check that the minimum flow of air through the facepiece is at
least 150 l/min.
Proceed as follows:
Connect the breathing hose to the control valve. Fig. 3.
o
Connect the compressed air supply tube to the control
o
valve. Fig. 4.
Turn the control valve knob anti-clockwise as far as it will
o
go, in order to throttle the airflow rate to a minimum. Fig. 3.
Place the facepiece in the bag and grip the opening of the
o
bag so that it seals around the breathing hose.
Grip the flow meter with the other hand and hold it so that
o
it points vertically up from the bag. Fig. 2.
Read the position of the ball in the tube. It should float level
o
with or just above the marking on the tube.
Ordering No.
R03-1534
If the flow rate is below the minimum value, check that
-
• the flow meter is vertical,
R03-1530
• the ball can move freely,
R03-1531
• the air supply is not restricted by kinks or other restrictions
R03-1510
in the hoses.
T01-3008
3.3 Donning
R03-1535
R03-0346
Belt/control valve
R03-1405
• Put the belt on and adjust the length.
• Arrange the control valve in a way that allows easy adjustment
of the flow rate and a strict watch over the breathing hose, i e.
it must not be placed on the back of the waist.
-
H02-1312
Filter
H02-0312
Fit a suitable filter in the filter attachment. Fig. 1.
T01-2001
R03-1406
Mask – Fit check
R01-2202
Check the fit of the mask if you intend to use a back-up filter:
R01-2001
Blank off the filter by using the sealing cover
R01-0605
• Put the mask on and
R01-2201
deep breath and hold your breath for ten seconds.
• If the mask is tight, it will be pressed against your face.
R01-2201
-
If any leakage is detected, check the inahalation and
-
exhalation valves, adjust the straps of head harness or
-
switch to alternative size of the respirator. Repeat the fit
R09-0101
check until there is no leakage.
-
-
Breathing hose/compressed air supply tube
-
• Connect the breathing hose of the facepiece to the control
H09-0401
valve outlet. Fig. 3.
H03-2810
• Unroll the compressed air supply tube and make sure that it
is not twisted.
• Connect the compressed air supply tube to the control valve
inlet. Fig 4.
Mask – Fitting
• Put on the mask and adjust the head harness strap until the
mask fits well and comfortably. Fig. 5.
• The retainment clip on the breathing hose is ideal for
fastening the hose close to the body. Fig. 1:1a.
Airflow rate
• Use the control valve knob to set the air flow rate to suit your
current work intensity. Fig. 3. In the fully closed position (turn
the knob anti-clockwise), the flow is about 150 l/min. In the
fully open position (turn the knob clockwise), the flow is
about 320 l/min.