Master/Slave Operation; Rdm - EuroLite LED IP Atmo Blinder 9 Bedienungsanleitung

Wetterfester blinder mit pixelansteuerung und atmo-cluster
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Table 1
Dimmer
0—255
Strobe
0—255
Macro
0—255
Speed
0—255
CTO
0—255
CW
0—255
WW
0—255
R1
0—255
G1
0—255
B1
0—255
R2
0—255
G2
0—255
B2
0—255

Master/slave operation

Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit. For this, set each Slave device to the same
DMX address (for example 001) and confirm with ENTER.
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Select the show mode Auto at the master unit. The interconnected devices will now operate
synchronously.

RDM

With this function, you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated in the DMX-transmission line without influencing the connections. New DMX-cables are
not necessary. RDM ready and conventional DMX devices can be operated in one DMX line. The RDM
protocol sends own packages in the DMX512 data feed and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
Table 2
IP Address A
002
IP Address B
192
IP Address C
168
IP Address D
001
Get way A
255
Get way B
000
Get way C
000
Get way D
000
Net DNS A
000
Net DNS B
000
Net DNS C
000
Net DNS D
000
MAC A
000
MAC B
000
MAC C
000
MAC D
000
Sub Uni
000
Net
000
DHCH
ON / OFF
31/40