RF Rx SW868/SW915/SW917/SW922-4W 24VAC/DC
//
Montage- und Anschlussanleitung / Funk-Empfänger
Mounting and wiring instructions / Wireless receiver
Instructions de montage et de câblage / Récepteur sans fil
Istruzioni di montaggio e collegamento / Ricevitore wireless
Instruções de montagem e instalação / Receptor sem fio
English
Antenna
Use suitable antennas only:
Device
Antenna
SW868/922
Antenna with cable and SMA
plug-in connector
SW915/917
Antenna with cable and SMA
plug-in connector
Mount the antenna on a metal plate. The metal plate serves as an
HF counterweight. Minimum size of metal plate: 250 x 250 mm. Note
minimum sideways distance to nearest wall or disturbance source:
>300 mm. Do not bend or clamp the cable. Minimum bending range of
cable: >25 mm.
Assignment of locations and radio frequencies:
Device type Radio frequency
SW868
868.3 MHz
SW915
915.0 MHz
SW917
917.0 MHz
SW922
916.5 MHz
Design of wireless range
The radio signal is attenuated on the way from the transmitter to the
receiver. In addition, the radio signal is influenced by obstacles. The
degree of attenuation depends on the material of the obstacle. The fol-
lowing tables serve as a guide.
Penetration of radio signals:
Material
wood, gypsum, glas uncoated
brick stone, press boards
armoured concrete
metal, aluminium lamination, water
Typical ranges:
Place of use
in free field (SW868/915/917 LR)
in free field (SW868/915/917 ULR)
in free field (SW922 LR)
in free field (SW922 ULR)
Mat. No.
1188958
1188987
Location
According to
EU
2014/53/EU (RED)
USA
FCC
Canada
IC
Mexico
IFT
Brazil
ANATEL
Japan
ARIB STD-T108
Penetration
90...100 %
65...95 %
10...90 %
0...10 %
Wireless range (approx.)
450 m
700 m
150 m
230 m
Place of use
indoors (SW868/915/917 LR)
indoors (SW868/915/917 ULR)
indoors (SW922 LR)
indoors (SW922 ULR)
To get the maximum range: use the specified antennas. With other an-
tennas, the maximum range may differ.
Safety
Do not use the device in connection with other devices whose direct or
indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets.
N.B.
Subject to technical modifications. Reconstruction and alterations to
the device are not allowed. It is the responsibility of the manufacturer
of a plant or machine to guarantee the correct general function.
Variants
Mat. No.
Variant
1244986
RF Rx SW868 4W 12 VDC Status monitoring
1319798
RF Rx SW868 4W Battery/Status monitoring
In these variants the status monitoring or status and battery monitor-
ing functions are always activated (factory setting of status monitoring
to 10 s).
Start-up
Requirements:
- Mount device on standard DIN rail.
- Connect cable for supply voltage 24 VAC/DC.
- A maximum of 40 transmitters can be taught in parallelly.
- The green LED indicates operational readiness.
The orange LED indicates the state of the output:
Off - Transmitter taught in, but inactive
On - Transmitter taught in, active
LED 1 flashes - No transmitter taught in
Select operation mode
There are nine different operation modes (see table). They may be se-
lected only after switch-on of the receiver. Operation modes may be
selected during configuration mode only. The relay functions can be
combined with the transmitter functions.
1. To start the receiver in configuration mode and select an operation
mode: press push-button S1 and keep it pressed. Switch on the sup-
ply voltage. Once the LED MD is blinking: release push-button S1.
Operation mode changes consecutively every 5 s automatically or by
pressing push-button S2. For display of the LEDs: see table.
2. If the desired operation mode is displayed, press the push-button S1
for 1 s. The desired operation mode is now activated. If S1 is not ac-
tuated within 5 s, it is switched to a different operation mode.
4 / 24
Wireless range (approx.)
40 m
50 m
20 m
25 m
Inhaltsverzeichnis