20161216
UN Manual of Test and Criteria, Part III, sub-section 38.3
;}#.
/.,$J(
NO.
iJ\~Jlll
§
;fo~*
Tests Item and Requirement
iJ\~~*
Result
!foIJJE
Conclusion
,
*!Ii-fj
19 -
!Ii-fj/lJiiJflfif(£, jn#tEjnF(a) ,
(b), (c) tfJlfif(£, jjIJ
N
1!J!jf;
4'
jPJ !Ii -fj j}}JI/
i!1
IfII!!
i:4o
The difference between this type and the tested type:
-
. Cells or batteries which differ from a tested
.type by as followes. shall be considered a new type
4nd shall be subjected to the required tests.
-
-
-38.3.2.2
(a) jJ)j
tl1,
/IiJ
tl1
J£
JfJ/IIIlIi
111fiI:G.Jl!
NO.1
J3 J£
2 0
%
!llJEff;
(t;)
iX7cif
jf;
Iff);
For primary cells and batteries. a change ofmore
than 0.1 g or 20% by mass, whichever is greater, to
the cathode. to the anode, or to the electrolyte;
-
-
(b)
x1T
Ji
JfJ JfJ
It!J
fn
f/!,
M
ffj,
1ft:
1ff-1\
fI1 tfJ
i&5£1il
N20%, ![(!f.1Bi Jf1 j;p Jlf!
N
2 0% ;
(b) For rechargeable cells and batteries, a change in
nominal energy in Watt-hours of more than 20% or
an increase in nominal voltage ofmore than 20%; or
-
-
(c)
11
it
Jfl1f;lj
nfiJii:4tiii JI!
!1t15fff;
0
A change that would lead to failure of any of the
tests,
-
-
-38.3.4.1
riv6i1tJfJ
(A~titude
simulation)
iHtr
Pass
3fjJJf!JfJjiJ!!k
(no mass loss)
~0.039%
-g-~
Pass
xiWlJIi
(no leakage)
x~iffi
no leakage
-g-tt§.
Pass
3fjllfE[
(no venting)
XMF~
no venting
-g-tt§.
Pass
xMit
(no disassembly)
xm1*
no disassembly
-g-t!
Pass
xli!t!ll
(no rupture)
x1i!t~
,
no rupture
-g-tt§.
Pass
xtf.f~
(no fire)
x1f&1;Jt
no fire
-g-tt§.
Pass
ii:4t /if
tfJ
7fi$
JfJBi
/f\
1\ T Jt
tE
i!1IT it
~
ii:4t
Jf!J JfJ
BitfJ90%
the open circuit voltage of each test cell or battery
after testing is not less than 90% of its voltage
immediately prior to this procedure
:;::::100.00%
-
-g-tt§.
Pass
...
Test Report_UN 38.3(6ndLENer5.0
1:,t::ffjEl.l\ll: 2016i:f:12JJOIEl