Herunterladen Inhalt Inhalt Diese Seite drucken

Safety; Scope Of Delivery; Intended Use; Product Information - Maico DAR 63/4 Montage- Und Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1 Safety

1 Safety
• Read these instructions and the enclosed
safety instructions carefully before installa-
tion.
• Follow the instructions.
• Pass these instructions on to the owner/operat-
ing company for safekeeping.
The fan may only be installed, set up, retrofitted,
commissioned, cleaned, serviced or repaired by
installers specialised in ventilation techno-
logy. Electrical connection, commissioning, main-
tenance and repairs may only be carried out by a
qualified electrician in accordance with DGUV
regulation 3, Section 2 (3) and in compliance with
the relevant standards (e.g. DIN EN 50110-1) and
technical rules. Further provisions of other na-
tional laws must be taken into account.
Qualifications, requirements: Specialist training
and knowledge of compulsory technical stand-
ards, EU Directives and EU Ordinances. The in-
stallations must be carried out professionally. Ap-
plicable accident prevention regulations, occupa-
tional health and safety measures (protective
clothing in good repair etc.) must be observed. In-
stallation work by trainees is only permitted under
the supervision of the above-mentioned trained
specialists.
Obligations of the installer and operating
company
The fan must be regularly inspected, cleaned and
maintained by a person qualified in accordance
with these instructions. Cleaning and mainten-
ance intervals should be determined by the
operating company. Frequency depends on am-
bient conditions and anticipated impairments.
Shorten the maintenance intervals in the event of
dust or a corrosive atmosphere. Additional safety
requirements should be observed during mount-
ing and operation, e.g. in accordance with EN
60079-14: Design, selection and erection of elec-
trical installations or national accident prevention
regulations.
These instructions and the enclosed safety in-
structions must be easily accessible so that both
installers and operators can refer to them quickly.
It is essential that these instructions are read be-
fore any work is undertaken on the fan.
Assemblies/components in the instructions
are not shown in their actual colours. Colours
are used to identify associated assemblies/
components.

2 Scope of delivery

• DAR duct fan
• Circuit diagram in the terminal box
• These installation and operating instructions
• Safety instructions supplement for industrial
fans

3 Intended use

DAR axial duct fans are used in commercial and
industrial ventilation. Areas of application include
ducted systems that require a large air flow with a
relatively low pressure drop (ventilation and cool-
ing systems in industry, shipping, commerce or in
civil/energy sectors). Any other use or use that
goes beyond this is considered improper use.
The DAR series consists of different type variants
with nominal widths 630 to 1600 mm and motors
of different polarity and power. DAR fans are
powerful and suitable for large air volumes.
Operation of the DAR is only permissible:
• for a permanent installation within a duct sys-
tem (any installation position);
• when mounted on walls or ceilings with suffi-
cient load-bearing capacity → accessories at
www.maico-ventilatroren.com;
• with permanent electrical installation;
• with sufficiently dimensioned vibration damping
measures;
• if flexible couplings are fitted between the DAR
and the duct system;
• with protection against accidental contact in ac-
cordance with EN ISO 13857, e.g. with SGRI or
SGCI protective grille, fitted if there is a free in-
let.

4 Product information

• Asynchronous three-phase AC motor 400 V
3 N PE
• S1 continuous operation (at constant load)
• Speed controllable by means of a frequency
converter
• Fan on/off with start/stop fixture (provided by
customer)
• Axial impeller with blades made of glass-fibre
reinforced, antistatic polyamide
With the DAD conversion kit accessory, the duct
fan can be converted to a roof fan → DAR conver-
sion to roof fan [} 19].
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis