Cleaning, care and maintenance

5.
Cleaning, care and maintenance
The appliance contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
6.

Troubleshooting

Problem
Cause
Room does not get
Temperature set too low
warm enough. Ap-
on the appliance.
pliance does not get
hot.
No power supply.
Room does not get
Overheating. High limit
warm enough al-
safety cut-out limits
though the appliance
heating output.
is hot.
Heat demand of the room
is higher than the appli-
ance output.
The room gets too
Appliance temperature is
hot.
set too high.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
16
| CWM M-F
Remedy
Check the selected room
temperature. Adjust if nec-
essary.
Check position of the ON/OFF
switch, RCD and fuse/MCB in
your fuse box.
Eliminate the cause (dirt or
obstructions at the air intake
or discharge). Observe mini-
mum clearances.
Remedy heat losses (Close
windows and doors. Avoid
constant venting.)
Check the selected room
temperature. Adjust if nec-
essary.

INSTALLATIoN

7.

Safety

Only qualified contractors should carry out the maintenance and
repair of this appliance.
7.1

General safety instructions

We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for the unit
are used.
WARNING Electrocution
Never operate the appliance in the immediate vicinity of
a bath tub, a shower or a swimming pool.
CAUTION Burns
Maintain the minimum clearances to adjacent objects.
Material losses
!
Ensure that the power cable is not in contact with any
appliance components.
7.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
8.

Appliance description

8.1

Standard delivery

The following are delivered with the appliance:
- Feet
9.
Installation
9.1

Minimum clearances

There must be at least 90 cm clearance between the appliance and
any combustible materials (e.g. curtains), walls or other adjacent
object surfaces.
www.stiebel-eltron.com