oPERATIoN

Cleaning, care and maintenance

5.3.3 Parameter
You can call up the following parameters:
display
description
P1
Room temperature offset
P2
Time format
P3
Temperature display unit
P4
Reset time programs (timer mode).
P5
Reset relative heating time
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a dif-
ference between displayed actual temperature I1 and the room
temperature you measure. To compensate for this difference, a
room temperature offset of ±3 °C can be set via parameter P1.
Example: The appliance indicates I1 = 21.0 °C. You have measured
a room temperature of 20.0 °C. There is a difference of 1.0 °C.
f To compensate for the difference, select an offset of P1 = -1.0.
P2: Time format
Parameter P2 allows you to specify whether the time is displayed
in the 12 hour or 24 hour format.
P3: Temperature display unit
Parameter P3 is used to specify whether the room temperature is
displayed in degrees Centigrade [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
6.
Cleaning, care and maintenance
The appliance contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
20
| EG-50-PL2-PE
7.

Troubleshooting

Problem
Room does not get
options
warm enough. Ap-
±3 °C | ±5 °F
pliance does not get
12 h | 24 h
hot.
°C | °F
on | off
on | off
Room does not get
warm enough al-
though the appliance
is hot.
The room gets too
hot.
Window open de-
tection does not
respond.
"Adaptive start" func-
tion does not work as
required.
"Err" or "E..." is dis-
played.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
Cause
Remedy
Temperature set too low
Check the selected room
on the appliance.
temperature. Adjust if nec-
essary.
No power supply.
Check position of the ON/OFF
switch, RCD and fuse/MCB in
your fuse box.
Overheating. High limit
Eliminate the cause (dirt or
safety cut-out limits
obstructions at the air intake
heating output.
or discharge). Observe mini-
mum clearances.
Heat demand of the room
Remedy heat losses (Close
is higher than the appli-
windows and doors. Avoid
ance output.
constant venting.)
Appliance temperature is
Check the selected room
set too high.
temperature. Adjust if nec-
essary.
Detected room tempera-
Avoid obstructions to air
ture does not match actu-
changes between appliance
al room temperature.
and indoor air.
Appliance does not detect
Wait a while after making
a pronounced tempera-
settings on the appliance,
ture drop when venting.
until the room temperature
(Window open detection
has fully stabilised.
requires a previously sta-
ble room temperature.)
Avoid obstructions to air
changes between appliance
and indoor air.
Manually switch the appli-
ance to standby mode for the
duration of venting.
Window open detection
Switch on window open
is not enabled.
detection in the standard
menu.
This function is only ef-
Use the timer mode for opti-
fective in timer mode.
mised heating convenience.
Severely fluctuating room
Wait a few days for the be-
temperature or the appli-
haviour to stabilise.
ance learning procedure
has not been completed.
"Adaptive start" function
Switch on the "Adaptive
is not enabled.
start" function in the stand-
ard menu.
Internal fault detected.
Notify the qualified con-
tractor.