Herunterladen Diese Seite drucken

Olympia LCD-8210 Bedienungsanleitung Seite 12

Wissenschaftlicher taschenrechner

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Enter REG mode (Quadratic regression)
(memory clear)
29
1.6
50
23.5
74
38.0
103
118.
46.4
REG
118
48.0
−35.599856934
(Regression Coefficient A)
1.495939413
(Regression Coefficient B)
−03
−6.71629667
(Regression Coefficient C)
16
−13.38291067
(
when xi = 16)
20
47.14556728
( when yi = 20)
175.5872105
(
when yi = 20)
2
Data input precautions
D
inputs the same data twice.
D
You can also input multiple entries of the
same data using
. To input the data
"20 and 30" five times, for example, press
20
30
5
.
D
The above results can be obtained in any
order and not necessarily that shown
above.
D
To delete data you have just input, press
.
Degrees, Minutes, Seconds calculations
D
You can perform sexagesimal calculations
using degrees (hours), minutes and se-
conds and convert between sexagesimal
and decimal values.
Example 1.: To convert the decimal value
2.258 to a sexagesimal value
2.258
2.258
2
0
15
0
28.9
0
J Technical Information
When you have a problem...
If calculation results are not what you expect or
if an error occurs, perform the following steps:
1.
(COMP mode)
2. (DEG mode)
3. (NORM 1 mode)
4. Check the formula you are working with to
confirm it is correct.
5. Enter the correct modes to perform the cal-
culation and try again.
If the above steps do not correct your problem,
press the P button on the back of the calculator
to reset it. Pressing the Reset" button deletes all
data stored in calculator memory. Make sure you
always keep written copies of all important data.
J Error messages
The calculator is locked up while an error mes-
sage is on the display. Press
to clear the error
or press
or
to display the calculation and
correct the problem.
Ma ERROR
Cause
D
Calculation result is outside the allowable
D
calculation range.
Attempt to perform a function calculation
D
using a value that exceeds the allowable
input range.
D
Attempt to perform an illogical operation
(division by zero, etc.)
D
Action
D
Check you input values and make sure they
are all within the allowable ranges. Pay spe-
cial attention to values in any memory
areas you are using.
11
Stk ERROR
D
Cause
D
Capacity of the numeric stack or operator
stack is exceeded.
D
Action
D
Simplify the calculation. The numeric stack
has 10 levels and the operator stack has 24
levels.
D
Divide your calculation into two or more se-
parate parts.
Syn ERROR
Cause
D
Attempt to perform an illegal mathematical
D
operation
Action
D
D
Press
or
to display the calculation
with the cursor located at the location of the
error. Make necessary corrections.
Arg ERROR
D
Cause
D
Improper use of argument
D
Action
Press
or
to display the location of
D
the cause of the error and make required
corrections.
J Order of operations
Calculations are performed in the following order
of precedence.
1. Coordinate transformation:
Pol (x, y) Rec (r, )
2. Type A functions: With these functions, the
value is entered and then the function key
is pressed.
2
−1
x
, x
, x!, ° '
y
3. Powers and roots: x
,
b/c
4. a
5. Abbreviated multiplication format in front of
, memory name or variable name: 2 , 5
A,
A etc.
6. Type B functions: With these functions, the
function key is pressed and then the value
is entered.
x
x
−1
,
, log, In.e
, 10
, sin, cos, tan, sin
,
−1
−1
−1
−1
cos
, tan
, sinh, cosh, tanh, sinh
,cosh
,
−1
tanh
, (−−)
7. Abbreviated multiplication format in front of
Type B functions: 2
3
, Alog2 etc.
8. Permutation and combination: nPr, nCr
9. X , ÷
10.+ −−
Operations of the same precedence are perfor-
x
X
med from right to left, e
In
120 > e
{In(
120)}.
Other operations are performed from left to right.
Operations enclosed on parentheses are perfor-
med first.
J Stacks
This calculator uses memory areas, called
"stacks", to temporarily store values (numeric
stack) and commands (operator stack) accor-
ding to their precedence during calculations. The
numeric stack has 10 levels and the operator
stack has 24 levels. A stack error (Stk ERROR)
occurs whenever you try to perform a calculation
that is so complex that the capacity of a stack is
exceeded.
Replacing the battery
D
Dim figures on the display of the calculator indi-
cate that battery power is low. Continued use of
the calculator when the battery is low can result
in improper operation. Replace the battery as
soon as possible when display figures become
dim.
12
To replace the battery
D
1. Press
to turn power off.
Screw
2. Remove the screws that
hold the battery cover in
place and then remove the
battery cover.
3. Remove the old battery.
4. Wipe off the side of the new
battery with a dry, soft cloth.
Load it into the unit with the
positive
side facing up
(so you can see it).
RESET button
5. Replace the battery cover
and secure it in place with
the two screws.
6. Use a thin, pointed object to press the Re-
set button. Be sure not to skip this step.
7. Press
to turn power on.
Auto power off
D
Calculator power automatically turns off if you do
not perform any operation for about six minutes.
When this happens, press
to turn power back
on.
J Input Ranges
Internal digits: 12
Accuracy: As a rule, accuracy is +/− 1 at the 10th
digit.
Functions
Input Range
10
DEG
0v|x|v 4.499999999 x10
sinx
RAD
0v|x|v 785398163.3
10
GRA
0v|x|v 4.499999999 x10
10
DEG
0v|x|v 4.500000008 x10
cosx
RAD
0v|x|v 785398164.9
10
GRA
0v|x|v 5.000000009 x10
Same as sinx, except when
tanx
DEG
|x|=(2n−1) x90.
Same as sinx, except when
RAD
|x|=(2n−1) x /2.
Same as sinx, except when
GRA
|x|=(2n−1) x100.
−1
sin
x
0x|x|x 1
−1
cos
x
−1
99
tan
x
0x|x|x 9.999999999 x10
sinhx
0x|x|x 230.2585092
coshx
−1
sinh
x
99
0x|x|x 4.999999999 x10
−1
cosh
x
tanhx
−1
0x|x|x 9.999999999 x10
−1
tanh
x
logx/lnx
0<x
xxx99.99999999
x
99
10
−9.999999999 x10
x
99
xxx230.2585092
e
−9.999999999 x10
100
0xxt1x10
2
50
x
|x|t1x10
100
1/x
|x|t1x10
;x00
100
|x|t1x10
x!
0xxx69 (x is an integer)
0xnx99, rxn (n,r is an integer)
nPr
99
1x{n!/(n−r)!}x9.999999999x 10
nCr
0xnx99, rxn (n,r is an integer)
49
|x|,|y|x9.999999999 x10
Pol(x, y)
(x2+y2)
x9.999999999 x10
99
99
0xrx9.999999999 x10
Rec (r,
)
:Same as sinx, cosx
13
100
|a|, b,c <1 x10
0xb,c
100
|x| <1x10
Decimal <>Sexagesimal Conversions
0
0
0
xxx999999
0
0
0
0
0
59
100
x>0:−1x10
<y long x < 100
x=0:y>0
1
x<0:y=n,
(n is an integer)
2n+1
00
However: −1x101
<y log|x|<100
y>0:x00
00
−1x101
<1/x log y<100
y=0:x>0
1
y<0:x=2n+1,
n
(n00: n is an integer)
00
However: −1x101
<1/xlog|y|<100
Total of integer, numerator and denomina-
tor must be 10 digits or less (including
division marks).
50
|x|<1x10
50
|y|<1x10
100
SD
|n|<1x10
(REG)
xón, yón, ,
A,B,r: n 00
xón−1, yón−1:n00,1
Note!
Error are cumulative with such internal continu-
x
3 3
ous calculations as
,
, X!, and
so accu-
racy may be adversely affected.
14
J Specifications
Power Supply:
Single G13 Type button battery (LR44)
D
Battery Life:
Approximately 12,000 hours continuous
D
display of flashing cursor.
Approximately 3 years when left with power
turned off.
Dimensions:
D
10 (H) x 76 (W) x 150 (D) mm
3/8" (H) x 3" (W) x 5
" (D)
7/8
Weight:
D
90 g (3.2 oz) including battery
Power Consumption:
D
0.0001 W
Operating Temperature:
D
0 °C ~ 40 °C (32 °F ~ 104 °F)
J Disposal Instructions
The incorporation of European
law into national legislation and
regulations imposes the obliga-
tion of appropriately disposing
of durable consumer goods.
This is intended as a means of
personal
and
environmental
protection.
The pictogram in the margin is
used to say that old electrical
and electronic units and batte-
ries should be kept separate
from your household waste.
Old appliances or equipment
at the end of its useful life
should be taken to the collecting
point of a suitable disposal
agency.
Old batteries should be taken to a shop where
batteries are sold or to a certified collecting point
where the appropriate containers are available.
Dispose of packaging material compliant to
local regulations.
J Warranty
Dear Customer,
we are pleased that you have chosen this device.
In the case of a defect, please return the device
together with the receipt and original packing ma-
terial to the point−of−sale.
15

Werbung

loading