2.4.5. Restoring the original configuration
͉
͉
Only perform a double power cut for the application to be
reset.
͉
͉
This reset deletes all control points, sensors and end limit
settings and resets the drive's AIR position.
1) Position the roller shutter at its half-way position.
2) Cut the power supply for 2 seconds.
3) Switch the power supply back on for 5 to 15 seconds.
4) Cut the power supply for 2 seconds.
5) Switch the power supply back on: the roller shutter
moves for several seconds.
6) Press the PROG button on the Somfy io-homecontrol
local control point for ≈ 7 s, until the roller shutter
moves up and down twice:
- The drive is reset to the original configuration.
Resume the commissioning operation (see Commissioning
section).
3. USE AND MAINTENANCE
This drive does not require any maintenance operation.
If no io-homecontrol® is programmed: contact a drive and home automation professional.
3.1. UP AND DOWN BUTTONS
Briefly pressing Up or Down raises or lowers the roller
shutter completely.
3.2. STOP FUNCTION
The roller shutter is moving.
my
• Briefly press
3.3. AIR POSITION
The AIR position, which allows the roller shutter to be placed in the Ventilated Locked Shutter
position, must be programmed in S&SO-RS100 AIR io during
the installation process.
To use the AIR position:
my
• Briefly press
stops in the AIR position.
3.4. ADDITIONAL SETTINGS
3.4.1. Deleting the AIR position
my
1) Briefly press
- The roller shutter starts to move and stops in the AIR
position.
my
again, for ≈ 5 s, until the roller shutter moves.
2) Press
- The AIR position has been deleted.
22
: the roller shutter stops automatically.
: the roller shutter starts to move and
.
Copyright
1)
3)
5)
®
6)
PROG. 7 s
1)
2)
5 s
©
2019 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
S&SO-RS100 AIR io
2)
OFF
5 s
4)
ON
OFF
15 s
ON
1 2
4 3
x 2
2 s
2 s
my
AIR