UK - Product information
This original installation instruction contains no construction documentation.
The following symbols are used in the instructions to draw attention to the risk of danger or damage to the product.
Prohibited symbol
Danger symbol
Disposal
4.1
Package contents
1 pc. RBV1.
1 pc. wireless outlet with remote control and battery.
1 pc. adaptor (only DK).
1 pc. assemble kit.
1 pc. installation and operation instruction for the RBV1.
1 pc. installation and operation instruction for the remote control.
4.2
Function
Scope
The RBV1 is a fan for mounting on top of the chimney. The RBV1 is designed to facilitate ignition
and refueling. It is designed for wood burning stoves or closed inserts with a nominal efect of
maximum 8 kW. The RBV1 comes with a lexible lange, a 5-meter cord prepared with plug, and an
integrated isolation switch.
Function
The RBV1 has been developed to solve draught problems by creating a mechanical draught on
chimneys with circular core and a maximum internal diameter of ø220 mm. The RBV1 is designed
to withstand high temperatures associated with wood burning at a max. temperature of 250 °C
and tolerates continuous operation on stoves and closed inserts.
The RBV1 must always be on during start-up (lighting the ire) and during refueling. When the
operating temperature in the ireplace, lue and chimney has reached a reasonable level and thus
created suicient draft, you may choose to switch of your RBV1. If you need extra draw-out later,
due to e.g. a change in weather, you simply turn on the RBV1 again, leaving it active as long as
necessary.
Start/stop can be accomplished by:
- a wireless outlet (included)
- a regular outlet (poss
Bad heating habits may result in problems, such as soot, chimney ires, etc., which may damage the
RBV1.
More information
www.exodraft.co.uk
WARNING
To avoid chimney ires – the chimney must be swept before mounting the RBV1!
As the RBV1 is part of a wood-ired installation, please ensure that the design meets the requirements
of fresh air supply. It is always recommend to install a smoke alarm in connection with a wood-ired
installation. Regardless of usage pattern, you must turn on your RBV1 at least once a month, allowing it
to run for 5-10 minutes. Inspect and clean your RBV1 installation at least once a year. The manufacturer
cannot be held responsible for water penetration into the chimney.
Failure to observe instructions marked with the prohibited symbol may result in ex-
treme danger.
Failure to observe instructions marked with the prohibited symbol is associated with
the risk of injury or material damage.
No special precautions. The product should be discarded in accordance with national
regulation for disposal of electronic waste.