Pull the trigger 9 until the paint comes out in
a straight stream.
Lock the paint spray gun 7 by turning the safety
catch 6 with the tip as far back and up as
possible.

Settings

You can use the pressure regulator dial 3 to
switch the appliance on by setting a level
greater than 0. The level you choose depends
on the spray material used. Determine the best
setting by carrying out a spray test.
The function switch e has two settings:
1. PRIME (vertical position): This setting
allows you to pre-fill the system with paint
or to depressurise the appliance.
2. SPRAY (horizontal position): You can use
this setting to work with the appliance.

Spraying

Unlock the paint spray gun 7 by turning the
safety catch 6 so that its tip is facing down.
To spray, press the trigger 9 and hold it down.
To stop spraying, release the trigger 9 again.
WARNING!
Always secure the paint spray gun 7 while
you are not actually spraying.
Lock the paint spray gun 7 by turning the safety
catch 6 with the tip as far back and up as
possible.

Overheating protection

The appliance has an overheating protection. It
switches the appliance off if overheating is immi-
nent. If this happens, carry out the following steps:
Turn the pressure regulator dial 3 to position
0 (off).
Turn the function switch e to the vertical posi-
tion (PRIME).
PAFS 550 A1
Let the appliance cool down for at least
30  minutes and, if necessary, remove the cause
of the overheating. This could be, for example,
an item that is covering the ventilation slots or if
the appliance is too close to a wall.
Put the appliance back into operation.

Depressurising the appliance

Always depressurise the appliance when you want
to take it out of operation. Depressurise the system
as follows:
Turn the pressure regulator dial 3 to position
0 (off).
Turn the function switch e to the vertical posi-
tion (PRIME).
Unlock the paint spray gun 7 by turning the
safety catch 6 so that its tip is facing down.
Release the pressure by pulling the trigger 9.
Hold the paint spray gun 7 over an empty
container while doing so.
Wait until all pressure and paint has been
dispelled from the system. To stop spraying,
release the trigger 9 again.
Lock the paint spray gun 7 by turning the
safety catch 6 with the tip as far back and
up as possible.

Eliminating suction problems

Press the valve trigger z 3–4 times to remove
any blockages or deposits from the valve.
If the problem persists: tap the connecting
thread r several times extremely carefully with
a rubber mallet (see fig. I) to loosen harder
deposits.