Herunterladen Inhalt Inhalt Diese Seite drucken

fm RX Serie Bedienungsanleitung Seite 56

Vorschau ausblenden Andere Handbücher für RX Serie:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Alarm Er05
Alarm Er06
Alarm Er09
Ed.:21 – Ver.:01 – 01/01/2021
-
If this alarm occurs when the device is on, a cooking cycle cannot be
started.
-
If the alarm occurs during a cooking cycle, it will be interrupted.
Alarm description:
No communication between the control module and the display.
Solutions:
-
Check the wiring between the control module and the display.
-
If the alarm persists, notify the Technical Assistance Service.
Major consecuences:
-
If this alarm occurs when the device is on, a cooking cycle cannot be
started.
-
If the alarm occurs during a cooking cycle, it will be interrupted.
Alarm description:
Chamber overheting. It occurs when the temperature of the chamber exceeds
310°C.
Solutions:
-
Wait for the oven to decrease in temperature.
-
If the alarm persists, notify the Technical Assistance Service.
Major consecuences:
-
If this alarm occurs when the device is on, a cooking cycle cannot be
started.
-
If the alarm occurs during a cooking cycle, it will be interrupted.
Alarm description:
Error de Firmware.
Solutions:
-
Notify the Technical Assistance Service.
Major consecuences:
-
If this alarm occurs when the device is on, a cooking cycle cannot be
started.
-
If the alarm occurs during a cooking cycle, it will be interrupted.
56
Inhaltsverzeichnis
loading

Inhaltsverzeichnis