17.
Safety instructions, transport and maintenance
17.1 Unpackaging
Visible damages: When receiving the material, enter a detailed description of the break in the PDA or in the
delivery note.
General comments such as "damaged packaging" or "damage can be seen", etc. will not be accepted. Clear
photographs showing the damaged good and packaging must be provided.
Hidden damages: When receiving the material and within 24 hours after reception, once the hidden damage has
been checked, photographs showing the damaged good and its corresponding packaging must be provided. The transport
agency label must be clearly visible. Photographs showing the content only and exclusively will not be accepted.
In either case, transport incidences should be reported to FM Industrial to manage the replacement of the machine.
If visible damages are detected when receiving the packaged machine, indicate "hits to the oven" at the time of the
delivery, take photos of the damages and transport agency label on the packaging. Please, contact FM Industrial
immediately.
If package is apparently in good conditions, and damages are detected when unpacking, place the original packaging
again on the machine, take pictures of the packaging and transport agency label on the packaging. Next, unpack again and
take photos of damages to the machine. Please, contact FM Industrial immediately.
17.2 Transport
Before transporting the unit to its installation site, make sure that:
-
Fits through the door
The floor withstands its weight
-
Transport should only and exclusively be carried out by mechanical means, such as a pallet jack, and always on a pallet.
17.3 Preliminary operations
Remove the protection film from the unit. Clean the adhesive residues with an appropriate solvent. Never use
abrasive or acid products or tools that may damage the surface.
17.4 Placing the unit
Place the oven in the selected work place and keep a safe distance as indicated below. Check that the unit has
sufficient cold air inlets through the ventilation registers ensuring correct operation. Otherwise, the unit may overheat,
and some components may be destroyed.
If the oven is installed on an auxiliary support, it must be fixed to it.
-
The facilities must be conditioned and meet the regulations in force with regard to safety in installations.
-
In addition, the unit must be protected from atmospheric agents
-
-
The ambient temperature may range between 5ºC and 35ºC maximum for correct operation of the unit
-
Humidity should not exceed 70%.
Ed.:21 – Ver.:01 – 01/01/2021
____
42