21.
Info and alarms (only for models RXD)
Alarm code
Alarm Er01
Alarm Er03
Alarm Er04
Ed.:21 – Ver.:01 – 01/01/2021
Alarm description:
Chamber probe
Solutions:
-
Check chamber probe.
-
Check connection of the probe till the chamber.
-
If the problema persists, replace probe.
Major consecuences:
-
If this alarm occurs when the device is on, you can not start a cooking
cycle.
-
If the alarm occurs during a cooking cycle, the cycle will stop
automatically.
Alarm description:
Safety thermostat
Solutions:
-
Check and reset safety thermostat manually
-
Check that the safety thermostat is correctly connected to the power
board.
Major consecuences:
-
If this alarm occurs when the device is on, a cooking cycle cannot be
started.
-
If the alarm occurs during a cooking cycle, it will be interrupted.
Alarm description:
Overheating power board
Solutions:
-
Verify that the oven is installed according to the safety distances indicated
in this manual and that there is no heat source near it.
-
If the alarm persists, notify the Technical Assistance Service.
Major consecuences:
________
Meaning
55