Herunterladen Inhalt Inhalt Diese Seite drucken

Lcd Display; On/Off And Autotest; Pressure Relief Valve - Osprey SOELDEN Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MICRO USB-C
PORT
The
micro-USB-C port (5V – 3A)
Charging can be completed with a standard
the
micro-USB-C
cable takes priority over recharging via the 2
The SuperCapacitors can be recharged with the
4
ON / OFF AND AUTO-TEST
5
ON / OFF AND AUTO-TEST
To turn on the
OSPREY ALPRIDE E2 AIRBAG System,
To turn on the E2 System, use the ON / OFF switch. This safety switch
This safety switch prevents undesired activation inside the bag. Pull the
prevents undesired activation inside the bag. Pull the switch up, turn it
switch up, turn it clockwise and hold for 2 seconds.
clockwise and hold for 2 seconds.
Each time it is turned on, the
OSPREY ALPRIDE E2 AIRBAG System
Each time it is turned on, the E2 System conducts an auto-test to verify
an auto-test to verify that the motor, SuperCapacitors and electronics are
functioning properly.
that the motor, SuperCapacitors and electronics are functioning properly.
During this self-test, the 3
LEDs
During this self-test, the 3 LEDs light up chronologically to check that the
LEDs
are functioning. Simultaneously, the
LEDs are functioning. Simultaneously, the LCD display blinks to check
the
LCD
display is working properly and all icons are visible.
that the LCD display is working properly and all icons are visible.
During this auto-test, the motor completes a first rotation at lowspeed,
During this auto-test, the motor completes a first rotation at low
switching on the green LED.
speed, switching on the green LED.
If the auto-test is succesfully completed, the motor rotates a second time and the green / orange
If the auto-test is succesfully completed, the motor rotates a second time and the green / orange LED will blink
>The system is ready for use.
>The system is ready for use.
If the auto-test detects a malfunction, the motor will rotate 4x and the red
If the auto-test detects a malfunction, the motor will rotate 4x and the red LED will remain on There is a problem in the system and it is not
problem in the system and it is not operational.
operational.
If the system detects a malfunction and it is charging, the red LED will remain on and the orange LED will blink rapidly.
If the system detects a malfunction and it is charging, the red
If there is a failure during the self-test, the following icon will be displayed on the LCD:
If there is a failure during the self-test, the following icon will be displayed on the LCD:
To turn the system OFF, pull the switch and turn it clockwise (same procedure as for turning ON). The motor will rotate 1 x and the red
To turn the system OFF, pull the switch and turn it clockwise (same procedure as for turning ON). The motor will rotate 1 x and the red LED will turn
on and off again to indicate that the system has shut down.
on and off again to indicate that the system has shut down.
NOTE: The LED blinking speed indicates that the system is either charging (2 x per second) or in standard ON mode (1 x every 3 seconds).
NOTE: The
LED
blinking speed indicates that the system is either charging (2 x per second) or in standard ON mode (1 x every 3 seconds).
TERRAIN USE AND LED STATUSES
TERRAIN USE AND
LED
To use the OSPREY ALPRIDE E2 AIRBAG system on terrain, you will need to:
To use the E2 System on terrain, you will need to:
To use the
E2 System
on terrain, you will need to:
1- Turn ON the
E2 System
(see section 5)
1- Turn ON the E2 System (see section 5)
2- Verify that the auto-test is okay (see section 5)
2- Verify that the auto-test is okay (see section 5)
If the green
LED
blinks, the system is operational with at least six hours of autonomy.
If the green LED blinks, the system is operational with at least six hours of autonomy
If the orange
LED
blinks, the system is operational with less than six hours of autonomy.
If the orange LED blinks, the system is operational with less than six hours of autonomy.
If the red
LED
blinks, the system cannot guarantee 100% inflation (but it will still attempt to inflate the airbag as much as possible).
If the red LED blinks, the system cannot guarantee 100% inflation (but it will still attempt to inflate the airbag as much as possible).
If the red
LED
remains on, the system is defective and should not be used.
If the red LED remains on, the system is defective and should not be used.
NOTE: The
LED
blinking speed indicates that the system is either charging (4 x per second) or in standard ON mode (1 x every 10 seconds).
NOTE: The LED blinking speed indicates that the system is either charging (2 x per second) or in standard ON mode (1 x every 3 seconds).
To activate the airbag inflation, pull hard (between 5 to 10 kg) on the activation trigger.
To activate the airbag inflation, pull hard (between 5 to 10 kg) on the activation trigger.
LCD
DISPLAY
6

LCD DISPLAY

5
6

PRESSURE RELIEF VALVE

The pressure relief valve is a solenoid-type electric valve and is active 3 minutes after the end of inflation for a maximum of 10 minutes or less depending
on the residual energy in the batteries or SuperCapacitors. It will then close automatically.
As soon as the valve is activated, the following icon appears on the
The purpose of this valve is to reduce the airbag pressure 3 minutes after inflation. This is to reduce the stress on the seams and fabric of the airbag,
ensuring a longer lifespan inflation after inflation.
The pressure relief valve also allows passive and partial deflation of the airbag by reducing its pressure but does not allow complete deflation of the airbag.
The operation of the pressure relief valve is controlled 3x during each self-test and can be clearly heard from the characteristic ticking noise (like a
Swiss watch!)
OSPREY / ALPRIDE E2 AIRBAG SYSTEM | Owners Manual
makes it possible to recharge the SuperCapacitors using the
USB-C
charger (not included), like those used for cell phones. Recharging the SuperCapacitors with
AA
micro-USB-C
cable even in the absence of the
use the ON / OFF switch.
light up chronologically to check that the
LCD
display blinks to check that
STATUSES
SuperCapacitor charge level
SuperCapacitor charge level
A A battery power level: if the batteries are missing or completely empty, the icon blinks
AA
battery power level: if the batteries are missing or completely empty, the
icon blinks to indicate that batteries need to be changed or installed.
to indicate that batteries need to be changed or installed.
Displays when the pressure relief valve is triggered
Displays when the pressure relief valve is triggered
Displays if the self-test is not functioning
Displays if the self-test is not functioning
Displays when the
Displays when the USB-C cable is connected and powered
USB-C / micro-USB-C
batteries.
AA
batteries.
conducts
LED
will remain on. The red LED light identifies there is a
LED
will remain on and the orange
USB-C
cable is connected and powered
LCD
display.
cable provided.
LED
will blink
LED
will blink rapidly.
LED
will turn

Werbung