BIR 01- _ _ _ _ -K12LL3-000S04
Inductive Rapid Positioning System
9

Technical data

The specifications are typical values for
BIR 01- _ _ _ _ -K12LL3-000S04 at 24 V DC, room
temperature and a nominal length of 500 mm in
conjunction with the targets BAM TG-IR-036-A,
BAM TG-IR-036-B, BAM TG-IR-037-A and
BAM TG-IR-037-B.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Typ. temperature
coefficient
2)
Shock rating as per
EN 60068-2-27
3), 4)
Continuous shock per
EN 60068-2-27
3), 4)
Vibration per
EN 60068-2-6
3), 4)
Protection per IEC 60529
(when threaded together)
9.2

Detection range/Measuring range

Measuring length
5)
Resolution
Repeat accuracy
Measuring frequency
Non-linearity
Detectable speed
9.3

Electrical data

Operating voltage U
b
Current draw
(at 24 V DC, no load
current)
Power consumption
Overvoltage protection
Voltage-proof up to
(GND – Housing)
www.balluff.com
1)
−40...+85 °C
−40...+85 °C
≤ 95%, non-condensing
≤ 30 ppm/K
100 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
IP67
200, 300, 500 and 600 mm
1 µm
≤ 1 µm
≥ 10 kHz
≤ ± 100 µm
≤ 10 m/s
10...30 V DC
≤ 70 mA
≤ 2.0 W
U
to 36 V
b
500 V DC
9.4

Electrical connection

Short circuit protection
to GND and 36 V
Reverse polarity
U
protected
6)
9.5

IO-Link interface

Transfer protocol
1.1
Transmission rate
COM3 (230.4 kBaud)
Cycle time
≥ 1 ms
Output value
Position in µm
Data format
32 Bit signed
Error value
0x7FFFFFFC
9.6

Materials

Housing material
Anodized aluminum
Plastic (PBT-GF30)
Material, active surface
Plastic (PBT-GF30)
9.7

Mechanical features

Weight (depends on
Approx. 2 kg/m
length)
Housing mounting
Mounting clamps and
screws
Tightening torque
2 Nm
For UL: Use in enclosed spaces and up to an altitude of 2000 m above
1)
sea level.
Measuring length 500 mm, target in the middle of the measuring range
2)
Individual specifications as per Balluff standard
3)
Resonant frequencies excluded
4)
5)
Currently available measuring lengths: 200 mm, 300 mm, 500 mm,
600 mm. Other measuring lengths in 100 mm increments are available on
request.
For UL: The BIR must be externally connected via a limited-energy circuit
6)
as defined in UL 61010-1, a low-power source as defined in UL 60950-1
or a class 2 power supply as defined in UL 1310 or UL 1585.
to 36 V