AIRFLOW INFORMATION

Note: The illustrations are for reference only. The product you have purchased
and the local conditions may differ from these.
1
Exhaust air into the
open
The exhaust duct should be as short and straight as possible.
To avoid excessive noise or reduced extraction performance, the diameter of
the exhaust duct should not be smaller than 150 mm.
Only use or shape arches with a large radius, small radii reduce the extraction
performance of the cooker bonnet.
Only use smooth piping or flexible hoses made of non-combustible material
for the exhaust air line.
If the exhaust air duct is laid horizontally, a minimum gradient of 1 cm per
metre or an angle of inclination of 2° must be maintained (Figure 3), otherwise
condensation can get into the extractor fan motor.
If the exhaust air is directed into an exhaust air duct, the end of the
connection piece must be aligned in the direction of flow.
If the extract air duct is routed through cool rooms, attics, etc., there may be
a large temperature gradient within the individual duct sections, resulting in
condensation or condensation water. Therefore, it is necessary to insulate
the exhaust air duct. In some cases, a condensation water barrier must be
installed in addition to adequate insulation.
The manufacturer is not liable for faults resulting from non-compliance with
the above instructions and regulations.
Use as recirculation bonnet
This appliance has been prepared for recirculation operation at the factory. To do
this, check inside the cooker bonnet that the activated charcoal filters have been
fitted to the right and left of the motor appliance.
2
Exhaust air via air
Angle of inclination of the exhaust
shaft/chimney
3
air duct
EN
35