Herunterladen Inhalt Inhalt Diese Seite drucken

Scandomestic KK 601 E Bedienungsanleitung Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Repair Guide:
Internal fan does not work
Temperature below the limits
LED lights do not light up
Light does not turn off
Led light flashing
Does not reach the temperature, but stops and starts
Suction line ice
• •
• •
22
2
• •
• •
If the malfunction continues after these checks, technical assistance should be requested from your
authorized dealer.
Please indicate the type of malfunction, type of appliance, serial number, and date of purchase
(invoice). The serial number and type of appliance are described on the equipment information
label (normally located inside the equipment, on the side).
In case of need for accessories or spare parts, you should also request them from your authorized
dealer, always mentioning the equipment data described above.
Note: For the protection of persons and property against direct/ indirect contacts, the use of a
differential protection of the power outlet directly to this equipment with a trip sensitivity of 300
mA is mandatory.
It is cold, it does not reach the temperature
Possible cause / repairs
Fan wires off /Check connection
Incorrect wire in the thermostat
Door open (door open alarm/ close the door and see door micro connection)
Faulty fan/ Replace fan
Faulty Digital thermostat relay/ Replace digital thermostat
Temperature of evaporator above
Fan stuck/
fan position
Check
Set Point temperature /
Wrong thermostat connections /
Safety thermostat/ See position
Glass door Thermostat/ Press AUX
Opaque door/ Close door
Incorrect transformer wires/ Check Connections
Faulty transformer/ Replace transformer
Faulty Led lights / Replace led lights
Too much
gas/Check
fan off/ Wait for equipment to cool down
10ºC,
settings
Check
connections
Check
door
open
gas charge