Technical Data

Rotary Hammer
Article number
Rated power input
Rated speed
Impact rate
– Drilling mode
– Chiselling mode
Impact energy per
stroke
– Drilling mode
– Chiselling mode
Chisel positions
Tool holder
Lubrication
Max. drilling dia.
– Concrete (with twist
drill)
– Concrete (with break-
through drill bit)
– Brickwork (with core
bit)
Weight according to
EPTA-Procedure
01/2003
Protection class
The values given are valid for nominal voltages [U] of
230/240 V. For lower voltage and models for specific
countries, these values can vary.
Please observe the article number on the type plate of
your machine. The trade names of the individual ma-
chines may vary.

Declaration of Conformity

We declare under our sole responsibility that the
product described under "Technical Data" is in
conformity with the following standards or
standardization documents: EN 60745 according
to the provisions of the directives 2004/108/EC,
98/37/EC (until Dec. 28, 2009), 2006/42/EC
(from Dec. 29, 2009 on).
Bosch Power Tools
GBH 5-40 DE
Professional
0 611 241 7..
W
1100
rpm
170–340
bpm
1700–3100
bpm
1700–3300
J
2–9
J
2–10
12
SDS-max
Oil lubrication
mm
40
mm
55
mm
90
kg
6.2
/ II
Technical file at:
Robert Bosch GmbH, PT/ESC,
D-70745 Leinfelden-Echterdingen
Dr. Egbert Schneider
Senior Vice President
Engineering
03.07.2007, Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Assembly
Before any work on the machine itself, pull
the mains plug.

Auxiliary Handle

Operate your machine only with the auxiliary
handle 9.
The auxiliary handle 9 can be set to any position
for a secure and low-fatigue working posture.
Turn the bottom part of the auxiliary handle 9 in
counterclockwise direction and swivel the auxil-
iary handle 9 to the desired position. Then
retighten the bottom part of the auxiliary handle
9 by turning in clockwise direction.
Changing the Tool
With the SDS-max tool holder, simpler and easier
tool changing is possible without additional aids.
The dust protection cap 1 largely prevents the
entry of drilling dust into the tool holder during
operation. When inserting the tool, take care that
the dust protection cap 1 is not damaged.
A damaged dust protection cap should be
changed immediately. We recommend hav-
ing this carried out by an after-sales service.
Inserting (see figure A)
Clean and lightly grease the shank end of the
tool.
Insert the tool in a twisting manner into the tool
holder until it latches itself.
Check the latching by pulling the tool.