Herunterladen Inhalt Inhalt Diese Seite drucken

Load Capacity - pewag Winner pro G12 Originalbetriebsanleitung

Standard-anschlagketten
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Special information regarding
the different programmes
Lifting chain pewag winner pro G12
Purpose: Mounting and lifting/transporting loads.
Temperature application range: -60 °C to 200 °C.

Load capacity:

Safety
I-leg chains
factor 4
Angle of
-
-
inclination β
Load factor
1
0,8
Code
d
Load capacity [kg]
WINPRO 7
7
2.360
1.900
WIN 7
7
1.900
1.500
Ni 7 G8
7
1.500
1.200
WINPRO 8
8
3.000
2.360
WIN 8
8
2.500
2.000
Ni 8 G8
8
2.000
1.600
WINPRO 10
10 5.000
4.000
WIN 10
10 4.000
3.150
Ni 10 G8
10 3.150
2.500
WINPRO 13
13 8.000
6.300
WIN 13
13 6.700
5.300
Ni 13 G8
13 5.300
4.250
The coefficient for the static test = 2.5 x load capacity respective of the chain segment.
Attention: the load capacity and in turn the test force for the static test of the individual chain segments
(e.g. an individual chain strand of a multi-leg lifting chain) differs from the total load capacity.
Reduction factors
The maximum load capacity of the chain sling arises from multiplying the load capacity on the tag with the
corresponding reduction factor according to the table as well as the accompanying factors in the table on page 28.
Temperature
Reduction factor
II-leg chains
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
0°–45°
45°–60°
0°–45°
45°–60°
1,4
1
1,12
0,8
3.350
2.360
2.650
1.900
2.650
1.900
2.120
1.500
2.120
1.500
1.700
1.200
4.250
3.000
3.350
2.360
3.550
2.500
2.800
2.000
2.800
2.000
2.240
1.600
7.100
5.000
5.600
4.000
5.600
4.000
4.250
3.150
4.250
3.150
3.550
2.500
11.200
8.000
9.000
6.300
9.500
6.700
7.500
5.300
7.500
5.300
5.900
4.250
-60 °C to 200 °C
1
III- + IV-leg chains
III- + IV- leg
chains with
load distributor
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
0°–45°
45°–60°
0°–45°
2,1
1,5
2,8
5.000
3.550
6.700
4.000
2.800
5.300
3.150
2.240
4.000
6.300
4.500
8.500
5.300
3.750
7.100
4.250
3.000
5.600
10.600
7.500
14.000
8.000
6.000
11.200
6.700
4.750
8.500
17.000
11.800
-
14.000
10.000
-
11.200
8.000
-
above 200 °C to 300 °C
0,6
Endless
Single
chain
lifting sling
sling
b
b
b
b
45°–60°
-
0°–45°
45°–60°
2
1,6
1,4
1
4.750
3.750
3.350
2.360
3.750
3.000
2.650
1.900
3.000
2.500
2.120
1.500
6.000
4.750
4.250
3.000
5.000
4.000
3.550
2.500
4.000
3.150
2.800
2.000
10.000
8.000
7.100
5.000
8.000
6.300
5.600
4.000
6.300
5.000
4.250
3.150
-
12.500
11.200
8.000
-
10.600
9.500
6.700
-
8.500
7.500
5.300
above 300 °C
not permissible
Double
lifting sling
E
0°–45°
45°–60°
2,1
1,5
5.000
3.550
4.000
2.800
3.150
2.240
6.300
4.500
5.300
3.750
4.250
3.000
10.600
7.500
8.000
6.000
6.700
4.750
17.000
11.800
14.000
10.000
11.200
8.000
35