5 Troubleshooting
Faults that affect the vacuum unit and its accessories are described in the CENTIX vacuum unit operating
instructions.
Fault
‡ Motor will not start
‡ Motor starts, but system
does not operate at origi-
nal power
16
Cause
> Control cable disconnected
>
Vacuum sockets not sealed
>
Tube system damaged
>
Glued connections to suction
tubes not tight
>
Test vacuum unit in mobile
operation. If full suction power
is available the tube system is
blocked.
>
Vacuum unit not providing full
suction power
Remedy
Check control cable (7) con-
nection to vacuum socket (10).
Check connection of 12V cont-
rol cable (7) coming from vacu-
um sockets to connector blocks
(14) with connecting cable (16)
to the CENTIX vacuum unit.
Check alignment of vacuum
socket and seals
Replace damaged tubes or
elbows
Re-glue the suction tubes
See CENTIX operating instruc-
tions
Contact Alto customer service