Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

9. Troubleshooting

Fault
Cartridge not transported
Cartridge strip cannot be
removed
Cartridge cannot be fired
Cartridge strip melts
Cartridge falls out of the
cartridge strip
Cause
■ Damaged cartridge strip
■ Carbon build up
■ Tool damaged
■ Tool overheated because of high
setting rate
■ Tool damaged
WARNING
Never attempt to pry a cartridge
from the magazine strip or tool.
■ Bad cartridge
■ Carbon build-up
WARNING
Never attempt to pry a cartridge
from the magazine strip or the tool.
■ Tool is compressed too long
while fastening.
■ Fastening frequency is too high
■ Fastening frequency is too high
WARNING
Never attempt to pry a cartridge
from the magazine strip or tool.
Possible remedies
■ Change cartridge strip
■ Clean the cartridge strip guide-
way (see 8.10)
If the problem persists:
■ Contact Hilti Repair Centre
■ Let the tool cool down and then
carefully try to remove the
cartridge strip
If not possible:
■ Contact Hilti Repair Centre
■ Manually advance the cartridge
strip one cartridge
If the problem occurs more
often: Clean the tool (see
8.3–8.13)
If the problem persists:
■ Contact Hilti Repair Centre
■ Compress the tool less long
while fastening.
■ Remove the cartridge strip
■ Disassemble the tool (see 8.3)
for fast cooling and to avoid
possible damage
If the tool cannot be disassembled:
■ Contact Hilti Repair Centre
■ Immediately discontinue using
the tool and let it cool down
■ Remove cartridge strip
■ Let the tool cool down.
■ Clean the tool and remove loose
cartridge.
If it is impossible to disassemble
the tool:
■ Contact Hilti Repair Centre
en
23

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Dx462hm

Inhaltsverzeichnis