Problem
The measured value does not
change.
"Device not connected" display
• The following list shows the formaldehyde effects depending on its concentration in the
ambient air:
0 – 0.08 ppm
Normal, healthy environment
0.09 – 1.99 ppm
Causes irritation of nasal and pharyngeal mucous membranes and
eyes
2.00 – 3.99 ppm
Stinging sensation in the eyes, nose and throat
4.00 – 5.00 ppm
Lacrimation, discomfort, tolerable for max. 30 minutes.
The above values are for reference only and may differ depending on the individual.
A concentration of 0.1 ppm should not be exceeded, not even briefly.
• Harmful formaldehyde concentrations can be reduced to harmless levels through ventilation.
The formaldehyde emission source should be located and removed.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste.
At the end of its service life, dispose of the product in accordance with applicable
regulatory guidelines.

Technical data

Port ...................................................................USB-C (OTG)
Measuring range ...............................................0.00 – 5.00 ppm
Resolution .........................................................0.01 ppm
Accuracy (+/- % of measuring range) ...............+/-5%
Operating system .............................................Android (version 6.0 or later)
Ambient conditions ...........................................0 to +50 °C/20 – 80% RH
Product dimensions (L x W x H) .......................33 x 62 x 14 mm
Weight ..............................................................approx. 20 g
Possible cause?
The meter is not connected.
Remedy: Disconnect the meter from the smartphone
and reconnect it. Follow the on-screen instructions.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2022 by Conrad Electronic SE.
2388642_V2_0322_02_m_VTP_en

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2388642

Inhaltsverzeichnis