Updating the firmware of the controller
As we are subject to a continuous improvement process, we have created the possibility for firm-
ware updates. If you are affected by such an update, please proceed as follows:
•
Switch to the „Bootloader" tab and press „Scan". The controller should then be listed in the list
of scanned devices with its ID. Here e.g. 0xF90BC5E2 at address 0xD1.
•
To be on the safe side, check the current FW version (here 1.0.0.29) via the „Get" button in the
Device Version area.
•
Use the button „Open" to search for the new image file in the explorer and select it for the up-
date (here BLDC_1.0.0.29.eff).
•
Then click on „Boot" -> LED turns yellow
•
Now click on „Flash". The progress bar will run from left to right and then confirm with „Comple-
te" -> LED turns green. Now the device is updated. As a rule, the configurations are not over-
written, but to be on the safe side, check this again as described in 6.4.
Brushless DC Controller HST-120
Orginal operating manual
Mounting and commissioning
Page 39 of 45
Rev1.3