Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Electrical Connection; Maintenance - Scheppach 5908207901 Original Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Removing the tool (Fig. 3)
• Pull back the locking sleeve (1) and hold it in place
and remove the tool.
Always keep chisel tools sharp.
Attention:
• Only work with low pressure when chiselling.
• Too much pressure puts unnecessary strain on the
motor.
• Sharpen chisels in good time and replace if
necessary.
Dust/chip extraction
Dusts from materials such as paint containing lead,
some types of wood, minerals and metal can be
harmful to health. Touching or inhaling the dust can
cause allergic
reactions and/or respiratory diseases of the user or
other people in the vicinity.
Certain dusts such as oak or beech dust are
considered carcinogenic, especially in combination
with additives for wood treatment (chromate, wood
preservatives). Material containing asbestos may only
be processed by specialists.
• Make sure that the work area is well-ventilated.
• It is recommended to wear respirators with filter
class P2.
Observe the regulations for the materials to be
processed applicable in your country.
9.

Operation

Danger!
To avoid a hazard, the machine may only be held by
the two handles (6/8)!
Switching on:Unlock the locking switch (5) and press
the on/off switch (4) to switch the engine on.
Switching off:Release the on/off switch (4).

10. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
22 | GB
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been
improperly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are
disconnected from electrical power when checking for
damage.
Electrical connection cables must comply with
the applicable VDE and DIN provisions. Only use
connection cables with the designation H07RN-F
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230-240 V~.
• Extension cables up to 25 m long must have a cross-
section of 1.5 square millimetres.
Connections and repair work on the electrical
equipment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Data of machine type plate

11. Maintenance

m Warning! Pull out the mains plug before carrying
out any adjustments, maintenance or repair work!
General maintenance tasks
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
www.scheppach.com

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ab1500x

Inhaltsverzeichnis