Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Flue - Fagor ADVANCE PLUS APG-061 Installationshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
INSTALLATION MANUAL ADVANCE PLUS
ENGLISH
GAS FLUE CONNECTION
Warning: An incorrect flue connection may lead to a fire hazard.
Gas appliances can be installed in different ways depending on the installation
requirements.
Gas oven installed in a local (Type A3)
Gas oven beneath a ceiling fan (Type B23)
This type of installation is made connecting it to a natural
draught, under a hood or a ventilation roof. It is required a
stretch of rising air.
Install the oven according to the kitchen layout. The gas
supply to the oven must only be enabled when the extraction
system is activated. When the extraction/ventilation system
fails, the gas feeding of the oven will be disabled.
Gas oven directly connected to an exhaust pipe (Type B13)
Convection ovens, or combined ovens with an anti-backflow valve (special
accessory), may be directly connected to an exhaust pipe. The accessory can
be ordered indicating the following references:
Oven Model 061/101:
Oven Model 102:
Oven Model 201:
Oven Model 202:
The gas oven should only be enabled when the extraction
system is activated.
Warning: Flues must be hermetically sealed. Use materials
that are thermally stable at temperatures of up to 400º.
User instructions:
The flue gas may have high temperatures, so that the exhaust gas and hot
metal parts can cause burns.
Do not place combustible materials on the apparatus; fire hazard.
It is recommended to install a gas oven beneath an
extractor hood.
Install the oven according to the kitchen layout. The gas
supply should only be switched on when the extraction
system is activated.
29
19012272
19012273
19012290
19012291

Werbung