INSTALLATION WITH SPINLOCK
Conventional assembly. (Instrument is put into the drill hole from the front).
The panel width may be within a range of 0.5 to 20 mm. The drill hole must have a diameter of 53 mm [B].
• Do not drill holes or ports in load-bearing or stabilizing stays or tie bars!
• Note the necessary clearance behind the drill hole or port at the installation location. Required
mounting depth: 65 mm.
• Drill small ports; enlarge and complete them, if necessary, using taper milling tools, saber saws, keyhole
saws or files. Deburr edges. Follow the safety instructions of the tool manufacturer.
1.
Different bezels may be installed as
alternatives to the supplied front ring. In this
case, gently remove the bezel using a
screwdriver [A] and install the new bezel on
the instrument and press it on until it is flush
with the instrument glass.
Note: the bezel cannot be used after removal
since it can be damaged.
IMPORTANT: if installing a chrome bezel,
make sure to configure the device BEFORE
installing it, as the metallic particles contained
in the chrome material might affect the NFC
performance!
A
C
WARNING
2.
Create a circular hole in the panel considering
the device dimensions. [B]
3.
Remove the spinlock and insert the device
from the front. [C]
4.
Adjust the spinlock ad shown in picture [D]
according to the panel thickness
5.
Carefully screw in the spinlock by hand at
least two turns.
6.
Insert the connector.
B
D
MECHANICAL INSTALLATION
B001025