Herunterladen Inhalt Inhalt Diese Seite drucken

GUDE Systems Expert Net Control 2111 Anleitung Seite 94

Inhaltsverzeichnis

Werbung

Spezifikationen
system panel port all set {OFF=0|ON=1}
system panel port all show
timer
timer enabled set {OFF=0|ON=1}
timer enabled show
timer syslog facility set {0..23}
timer syslog facility show
timer syslog verbose set {0..7}
timer syslog verbose show
timer {rule_num} enabled set {OFF=0|ON=1}
timer {rule_num} enabled show
timer {rule_num} name set "{name}"
timer {rule_num} name show
timer {rule_num} {FROM=0|UNTIL=1} set "{yyyy-
mm-dd}"
timer {rule_num} {FROM=0|UNTIL=1} show
timer {rule_num} trigger jitter set {0..65535}
timer {rule_num} trigger jitter show
timer {rule_num} trigger random set {0..100}
timer {rule_num} trigger random show
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} set "{time_date_list}"
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} show
timer {rule_num} action mode set {SWITCH=1|
CLI=2}
timer {rule_num} action mode show
timer {rule_num} action {SWITCH1=0|
SWITCH2=1} {OFF=0|ON=1} set "{port_list}"
timer {rule_num} action {SWITCH1=0|
SWITCH2=1} {OFF=0|ON=1} show
timer {rule_num} action delay set {0..65535}
timer {rule_num} action delay show
timer {rule_num} action console set "{cmd}"
timer {rule_num} action console show
timer {rule_num} action hash set "{data}"
timer {rule_num} action hash show
timer {rule_num} delete
timer delete all
vt100
vt100 echo set {OFF=0|ON=1}
vt100 echo show
vt100 numeric set {OFF=0|ON=1}
vt100 numeric show
vt100 reset
Hinweise
1. Legacy - Der Befehl ist von einer neueren Version abgelöst worden
2. Befehl kann auf allen Ebenen ausgeführt werden
3. Die Ausgabe kann 2 Zeilen umfassen - die erste Zeile zeigt den aktuellen Zustand,
die zweite Zeile den Status nach einem Neustart
4. Die Ausgabe kann mehrere Zeilen umfassen
5. N/A
6. Bitte die Tabellen Externer Sensor Feld und Externer Sensor Typ konsultieren,
um den richtigen Index zu finden
Externer Sensor Typ Tabelle "{sen_type}"
Konstanten "{7x01=0|7x04=0|7x02=1|7x05=1|7x06=2}"
Index
Beschreibung
0
Temperatur
0
Temperatur
1
Temperatur, Luftfeuchtigkeit
Expert Net Control 2111/2191
enable siwtch all relays from panel buttons
shows if siwtch all relays from panel buttons
enabled
enters cmd group "timer"
enables timer functions
shows if timer a enabled
sets facility level for timer syslog
shows facility level for timer syslog
sets verbose level for timer syslog
shows verbose level for timer syslog
enables rule
shows if rule is enabled
sets name of rule
shows name of rule
sets date range of rule
shows date range of rule
sets jitter for rule
show jitter of rule
sets probability for rule
shows rule probability
sets time date list
shows time date list
sets switch or cli cmd
shows if switch or cli cmd
sets port list for switch cmd
shows port list for switch cmd
delay between cmds
shows delay between cmds
sets cmd string
shows cmd string
sets action binary form
shows action binary form
delete one timer
delete all timer
enters cmd group "vt100"
sets console echo state
shows console echo state
sets numeric mode
shows numeric mode state
resets terminal
Produkte
7001, 7101, 7201
7004, 7104, 7204
7002, 7102, 7202
94
© 2021 GUDE Systems GmbH

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Expert net control 2191

Inhaltsverzeichnis