REFRESHING THE OIL
1. Start the motor for several minutes and then stop the motor.
2. Remove the oil filter cap.
3. Place the oil collect can under the motor, unscrew the oil drain plug and
drain the oil.
4. Replace the oil drain plug.
5. Fill with fresh oil up to the maximum level.
6. Replace the oil filter cap.

8. APPLICATION RANGE

AC application
Model 1 kW – 4 stroke
AC output
Rated voltage
Frequency
AC current
Rated output

9. TROUBLESHOOTING

50 Hz
230 V
50 Hz
230 V
50 Hz
230 V
Unit
V
Hz
A
VA
29
950
Power factor
850 W
700 W
800 W
Model 1 kW
230 V AC
50
3,8
850
1
0,7~0,8
0,7~0,95
12 V DC
-
10
120