Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions - HASE LIMA IQ+ Installationsanleitung

Vorschau ausblenden Andere Handbücher für LIMA IQ+:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en

INSTALLATION INSTRUCTIONS

LIMA
/ SILA
Distances to combustible materials
The following safety distances* are minimum values which must be observed
to ensure fire safety.
Observe the following safety distances (Fig. 1-3) for flammable
materials:
c
c
b
b
Safety distances from flammable materials
Front of stove
Side of stove
Back of stove
Ceiling/top edge of stove
Flue pipe connection
*Depiction of safe distances without rotary function.
**The safety distance is defined by the flue pipe manufacturer.
If not values are specified, the relevant Ordinance on Firing Installations applies.
/ SILA PLUS
Fig. 1
Fig. 2
Fig. 3
Abbreviation
Dimensions [cm]
a
110
b
53
c
24
d
75
e
**
When setting the stove up on flammable flooring (e.g. wood, laminate, carpet) a
floorplate (e.g. safety glass, steel, stone) must be used (Fig. 4):
g
Floorplate safety distances
Front of floorplate
Side of floorplate
NOTE: DISTANCE TO NON-FLAMMABLE MATERIALS
To avoid obstructing air circulation around the stove we recommend
a clearance of at least 5 cm in front of and next to the stove.
NOTE: TEMPERATURE-SENSITIVE MATERIALS
Temperature-sensitive materials such as glass or plastic may require greater
clearances than the safety distances specified.
The safety distances specified also apply for highly-insulated components
with a thermal insulation resistance of R ≤ 8 m²K/W.
Fig. 4
Abbreviation
Dimensions [cm]
f
50
g
23