Suggested Sag Measurements
Travel
45 mm (1.7 in)
11.25 mm (0.44 in)
55 mm (2.16 in)
13.75 mm (0.54 in)
65 mm (2.56 in)
16.25 mm (0.64 in)
75 mm (2.95 in)
18.75 mm (0.74 in)
Do not exceed maximum air pressure:
BOMBER AIR maximum air pressure is 350 psi.
AIR SLEEVE
ADDING AIR PRESSURE
Equalize the positive and negative air chambers by slowly compressing the shock through 25% of its travel
10-20 times after every 50 psi addition. Failure to equalize the chambers can result in greater pressure
in the positive air chamber than the negative chamber. If the shock feels very stiff and is in the topout
position, compress the shock until you hear or feel air transfer. Hold the shock in this compressed position
for a few seconds.
RELEASING AIR PRESSURE
Release air slowly so the air from the negative chamber can also be released through the Schrader valve.
Releasing the air pressure too quickly can cause the negative chamber to have more pressure than the
positive chamber. If the shock is compressed into its travel and does not fully extend, add air pressure
until the shock extends, then slowly compress the shock through 25% of its travel 10-20 times.
25% sag (Firm)
30% sag (Plush)
13.5 mm (0.53 in)
16.5 mm (0.65 in)
19.5 mm (0.77 in)
22.5 mm (0.88 in)