How to remove and re-install the air filter
This filter is placed before the air inlet and should
be cleaned regularly to keep the chamber clean.
1) Turn the filter screws counterclockwise to un-
lock the filter and take it out. Wash the filter with
lukewarm water with a mild detergent until it's
clean as possible. Let the filter dry before re-in-
stalling it.
2) Re-install the filter screen, place the filter
Filter
How to remove and re-install the splash shield
Warning: before removing or installing the shield,
make sure the microwave is unplugged from the
power outlet and the microwave is cool down.
1) Detaching: Hold the two buckle positions in front
of the splash shield with your hands (position in-
dicated by the arrows). Pull on the buckles in the
direction of the arrows. Once the buckles are out
Trouble shooting
The following events can be considered as normal
effects of working with this microwave.
• Radio and TV reception may be interfered when
the microwave is operating.
• The light of the oven might be dimmed when op-
Trouble
Microwave doesn't start
working
Oven doesn't heat
Filter screws
Possible cause
Power cord not plugged in correctly.
Fuse blown of circuit breaker active.
Power outlet defective
Door not closed correctly
screws and turn them clockwise to lock the filter
in position
3) The microwave has a function to remind users of
cleaning the filter every 30 days.
4) When the microwave display shows 'CLEAN FIL-
TER' check if the filter needs cleaning, to erase
this message from the display hold the 'pause'
button for 3 seconds.
Caution! Make sure the splash shield is inslled correctly
before use of the microwave oven!
gently take the splash shield down.
2) Wash the splash shield with lukewarm water
and mild detergent.
3) Installation: Pick up the splash shield and lock
the pins in the holes on the rear plate of the
chamber, move the splash shield in position and
re-attach the buckles.
erating.
• During heating steam can come from the food
and can accumulate on the cooler parts of the
microwave like for instance on the door.
Solution
Check if the power cord is plugged in
correctly.
Replace fuse or reset circuit breaker.
If not sure how to do this contact your
supplier.
Test outlet with other appliance and
check circuit breaker.
Check the door if it closes properly,
if it can't be closed properly contact
your supplier.
EN