5 Product information

5.5 ECA 150 ipro RC, ECA 150 ipro

KRC

• Small room fans for extracting air from rooms.
• Radio-controlled fan for the MAICOsmart ex-
haust air system.
• Model with radio receiver 868 MHz (EnOcean).
• ECA 150 ipro RC with fixed internal grille.
• ECA 150 ipro KRC with electrically operated
internal shutter.
• On/off via optional DS RC radio switch or sep-
arate RLS RC room air control.
• Two-level operation with optional radio switch
or separate room air control.
• Master-slave operation of the RC fans only
possible in ECA 150 ipro RC, RCH, KRC and
KRCH single-type systems (RLS RC room air
control required). Combinations with ECA 100
ipro RC/RCH and ECA 100 RC not permissible.
• Further product features → Unit versions
[} 25].

5.6 ECA 150 ipro RCH, ECA 150 ipro

KRCH

• Small room fans for extracting air from rooms.
• Radio-controlled fan for the MAICOsmart ex-
haust air system.
• Model with 868 MHz (EnOcean) radio receiver
and humidity control.
• ECA 150 ipro RC with fixed internal grille.
• ECA 150 ipro KRC with electrically operated
internal shutter.
• Barrier-free product as the fan switches itself on
and off via the humidity sensor.
• Switch-on humidity does not have to be set.
Fan monitors humidity curve. Automatic air ex-
traction depending on room humidity, at level 1
or 2.
• Two-level operation with separate DS RC radio
switch or separate RLS RC room air control,
also during humidity operating mode.
• Master-slave operation of the RC fans only
possible in ECA 150 ipro RC, RCH, KRC and
KRCH single-type systems (RLS RC room air
control required). Combinations with ECA 100
ipro RC/RCH and ECA 100 RC not permissible.
• Further product features → Unit versions
[} 25].

5.7 Unit versions

Unit
Start
Over-
ver-
delays
run
sions
[sec.]
time
of ECA
[min.]
150
ipro ...
Stand-
ard
VZC
0/50/90/
0/8/17/
120
25
H
0/50/90/
8/17/2
120*
5**
B
0/8/17/
25
RC
RCH
K
KVZC 0/50/90/
0/8/17/
120
25
KH
0/50/90/
8/17/2
120*
5**
KB
0/8/17/
25
KRC
KRCH
Bold Indicates delivery status
● Standard equipment
■ With optional light switch
* Start delay available when using an optional
switch (e.g. light switch).
** Overrun time of 0 min available when using an
optional switch (e.g. light switch).
*** When using additional switch 5 x 1.5 mm².
Mains
4 op-
speed
cable
erat-
con-
[mm²]
ing
trol-
pro-
lable
grams
5 x 1.5
5 x 1.5
3 x
1.5***
3 x
1.5***
3 x 1.5
3 x 1.5
5 x 1.5
5 x 1.5
3 x
1.5***
3 x
1.5***
3 x 1.5
3 x 1.5