The ETN 152/3 P is designed according to protective class II. For the user's
safety, the tool may be operated only with a leakage current protector. That
is why the tool includes an integrated PRCD protective switch.
Attention!
The PRCD protective switch must not lay in water.
!
PRCD protective switches must not be used to switch the
tool on and off.
Before starting your work, check the proper function by
pressing the TEST button
Use only three-conductor cable with earth conductor and sufficient cross
section (ref. to table). Too small a cross section may cause malfunction of
the tool.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
Prior to putting the tool into operation, check the mains voltage for
conformity with the requirements of the tool's nameplate.
Voltage variations between + 6 % and – 10 % are permissible.
The tool includes a start-up speed limiter to prevent fast expulsion fuses
from unindented responding.
Additional Handle
For manual drilling, the ETN 152/3 P may be used only together with its
additional handle which comes with the tools. Place it on the gearing collar
from the front and fix it by counterclockwise rotation.
Switching ON and OFF
Short-time operation
ON:
Press the ON/OFF switch
OFF:
Release the ON/OFF switch
Long-time operation
Electrical Connection
Cross section in sq. mm
1.5
20 m
50 m
21
2.5
40 m
80 m

Werbung