Coolant Supply F F o o r r m m A A F F / / J J F F
R R E E S S U U L L T T
Coolant supply is changed over to F F o o r r m m A A F F / / J J F F .
5 5 . . 3 3 . . 3 3 C C h h a a n n g g e e o o v v e e r r t t o o F F o o r r m m A A D D o o r r J J D D
Change over of the coolant supply from Form AF to Form AD.
W W A A R R N N I I N N G G
R R i i s s k k o o f f b b u u r r n n s s f f r r o o m m h h o o t t t t h h r r e e a a d d e e d d p p i i n n a a r r e e a a ! !
Serious burns and injuries can occur during heating and unscrewing the threaded pins.
Always wear ISO protective gloves when heating and unscrewing the threaded pins.
After heating, wait until the heated threaded pin area has cooled down.
Montage- und Betriebsanleitung
Montage- und Betriebsanleitung
Installation and Operating Instructions
Installation and Operating Instructions
Screw the threaded pins with medium-strength thread locking com-
pound (adhesive) into the cooled tool holder at "Pos. 2" (see
Coolant Supply F F o o r r m m A A F F / / J J F F
).
Remove any adhesive residues.
After the curing time of the adhesive, check the threaded pins for secure
fitting and rebalance the tool holder, if necessary.
Use a pull stud with coolant bore for the machine-side sealing of the
tool holder.