CELL INTERNAL FANS
INFORMATION
In the screen dedicated to the fans (figure42) it is
possible to view the status of the fans and the
operating mode during the conservation phase of the
machine.
It is also possible to obtain information on:
• to the signal supplied by the electronics to the fan.
• the speed of rotation of the blades (in rpm).
• the absorbed power.
• to the volumetric flow rate of the single fan.
• to the total volumetric flow rate of all the fans inside the
cold room.
TREND OF TEMPERATURES
In the "Temperature trend" screen (figure 43), it is
possible to view a graph that describes the trend of the
temperatures detected by the air probe and the core
probe. In particular, the Real Temperature Trend
describes in real time the temperature trend of the core
probe and the air probe. Each time the page is accessed,
the graph is reset.
It is also possible to access the historical temperature
trend from the home screen by clicking on settings. The
History Temperature Trend allows you to scroll
temporally the temperature trend and view the historical
data.
CYCLE CHANGES
In the screen dedicated to the modification of the cycles
(figure 44) it is possible to view the parameters that describe
the operation of a cycle. As soon as you click on the icon,
select the cycle you want to view / modify from the selection
bar. Once the cycle has been selected, modify the
parameters of interest and save it.
Changes made once saved are permanent.
ELECTRICAL CONSUMPTION INFORMATION
If the energy consumption option is enabled in this
section it is possible to have information on energy
consumption and active powers during machine
operation. In particular, it is possible to view:
• Total energy consumption [kWh].
• Instantaneous current power [Kw].
• Current reactive power [VAR].
FANS INFORMATION
Status: OFF
0.0
Rpm
0 (g / min)
Rpm
0 (kW)
42
Real Temperature Trend
65
30
- 5
- 40
00/00/0000
00/00/0000
0
43
ACTYVE CYCLE PARAMETERS
RATARDER PROOFER
° C
PHASE
1
0.0
0.0
0.0
0.0
2
0.0
0.0
3
44
DOOR OPEN INFORMATION
Energy meter: Total energy consumption
0.0
kWh
Actual Total Power
Actual Total Reactive
Power
45
00:00
00/00/0000
V.
Flow
0 (m ^ 3 / s)
installments
Tot. Flow
0 (m ^ 3 / s)
installments
00:00
00/00/0000
31
Cabinet Temperature
0.0 ° C
Core Temperature
0.0 ° C
00/00/0000
00:00
00/00/0000
° C
hh
mm
%
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00:00
00/00/0000
0.0
(kW)
0.0
(VAR)
73