> Bellow expansion joints have to be installed into the discharge line of the pump
(compensation of temperature, pressure ...).
4.2

Switching on/off of the centrifugal immersion pumps

Depending on type or installation situation the centrifugal immersion pumps are switched on
and off at the motor protection switch, the cable terminal box or the control of the system in
which the pump was integrated. Observe the instructions of the motor manufacturer.
5.

Variation in length depending on the temperature

As all materials will expand or contract with temperature variations, it is important to know
which minimum or maximum temperatures will be acceptable within the pump.
Extension of length in mm per 1000 mm pump immersion length
Temperature (°C)
-20
-10
0
10
20
30
40
50
60
70
80
90
100
Example:
Pump of 2000 mm immersion length in version with support tube in PP.
The pump must tolerate temperature variations in climate throughout the year,
i.e. 0°C in winter up to +40°C in summer.
The variation in length of the support tube will be: - 2 mm per 1000 mm in winter and
+ 3.6 mm per 1000 mm in summer. This means - 4 mm up to + 7.2 mm at a length of
2000 mm.
F 640 PP- ... / 185/230
Standard cover
10-706 45 063
Immersion length [mm]
PP
-4,00
-3,00
-2,00
-1,00
0,00
1,80
3,60
5,40
7,20
9,00
10,80
12,60
14,40
Special cover
only at housing
size 230
10-700 41 269
Operating instructions centrifugal immersion pumps
PVDF
S
-4,40
-0,66
-3,30
-0,50
-2,20
-0,33
-1,10
-0,17
0,00
0,00
1,30
0,17
2,60
0,33
3,90
0,50
5,20
0,66
6,50
0,83
7,80
0,99
9,10
1,16
10,40
1,32
F 640 PVDF- .../ 185/230
Standard cover
10-706 65 002
Immersion length [mm]
Special cover
only at housing
size 230
10-700 60 169
45 / 80