Herunterladen Inhalt Inhalt Diese Seite drucken

Kaco blueplanet 87.0 TL3 Kurzanleitung Seite 178

Vorschau ausblenden Andere Handbücher für blueplanet 87.0 TL3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
Abbreviations (en)
External hex
W
Internal hex
A
Torx
T
Slot
S
Tab. 1: Tool abbreviations legend
3.3
Fastening the mount
WARNING
Hazard when using unsuitable fixing materials!
If unsuitable fixing materials are used, the device could fall and persons in front of the device may be seri-
ously injured.
Use only fixing materials that are suitable for the mounting base. The fastening materials supplied are
only to be used for masonry and concrete.
Only install the device in an upright position.
4
Installation
4.1
Opening the device
↻ The device has been installed on the mount.
↻ Wipe any moisture off the frame of the housing cover using a cloth.
1 Undo the 6 screws (2) and carefully remove the housing cover (1) [
2 Be careful not to damage or soil the seals or optical fibers when setting the
housing cover down.
» Proceed with the installation of the device.
4.2
Making the electrical connections
NOTE
Select conductor cross-section, safety type and safety value in accordance with the following basic condi-
tions:
Country-specific installation standards; power rating of the device; cable length; type of cable installation;
local temperature
NOTE
All electrical installations must be carried out in accordance with local electrical standards and conform to
the National Electrical Code® ANSI / NFPA 70 or the Canadian Electrical Code® CSA C22.1.
This document does not replace any local, federal or national laws, regulations or regulations that apply to
the installation and use of the product, and is not intended to replace them, including the applicable electri-
cal safety regulations.
All installations must conform to the laws, regulations and standards that are applicable in the country of in-
stallation. KACO new energy does not assume any responsibility for compliance or lack of compliance with
such laws or codes in connection with the installation of the product.
Detailed information on tightening torques: See comprehensive operating instructions under
ergy.com/de/downloads
4.3
Connecting the device to the mains supply
Page 178
Contour of the
connecting element
Tightening torque
Spanner size or number
Outer contour
Fig. 1: Presentation format
T_25]
Fig. 2: Removing the housing
cover
Photovoltaik-feed-in inverter KACO blueplanet 87.0-165TL3
in-Ibs
1
2
http://www.kaco-newen-

Werbung

Inhaltsverzeichnis
loading