portsensor {port_num} {energy_sensor} publish
mqtt retain show
portsensor {port_num} {energy_sensor} publish
timer set {num_secs}
portsensor {port_num} {energy_sensor} publish
timer show
portsensor {port_num} {energy_sensor} publish
delta set {float}
portsensor {port_num} {energy_sensor} publish
delta show
portsensor {port_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num} set
portsensor {port_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
portsensor {port_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
portsensor {port_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
portsensor {port_num} events set {OFF=0|ON=1} LEGACY - enables sensor events on/off
portsensor {port_num} events show
portsensor {port_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
portsensor {port_num} events type show
portsensor {port_num} maxval set {num}
portsensor {port_num} maxval show
portsensor {port_num} minval set {num}
portsensor {port_num} minval show
portsensor {port_num} hyst set {num}
portsensor {port_num} hyst show
portsensor {port_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
set {port_num} set
portsensor {port_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
portsensor {port_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
show
portsensor {port_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
radius
radius {PRIMARY=0|SECONDARY=1} enabled set
<off=0/on=1>
radius {PRIMARY=0|SECONDARY=1} enabled
show
radius {PRIMARY=0|SECONDARY=1} server set
"<dns_name>"
radius {PRIMARY=0|SECONDARY=1} server
show
radius {PRIMARY=0|SECONDARY=1} passw ord
set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} passw ord
hash set "{passw d}"
radius {PRIMARY=0|SECONDARY=1} auth timeout
set {num_secs}
Expert Power Control 8001
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
sets pow er port for sensor values action
sets state for sensor values action
show s port for sensor values action
show s state for sensor values action
LEGACY - show s if sensor events are enabled
LEGACY - enables different event types
LEGACY - show s w hat event types are enabled
LEGACY - sets maximum value for sensor
LEGACY - show s maximum value for sensor
LEGACY - sets minimum value for sensor
LEGACY - show s minimum value for sensor
LEGACY - sets hysterese value for sensor
LEGACY - show s hysterese value for sensor
LEGACY - sets pow er port for sensor values
action
LEGACY - sets state for sensor values action
LEGACY - show s port for sensor values action
LEGACY - show s state for sensor values action
enters cmd group "radius"
enables radius client
show if radius client enabled
sets radius server address
show s radius server address
sets radius server shared secret
sets radius server crypted shared secret
sets server request timeout