Spezifikationen
epc8221ResetTime
epc8221Forw EnergyActive
epc8221Forw EnergyReactive
epc8221Forw EnergyActiveResett
able
epc8221Forw EnergyReactiveRes
ettable
epc8221RevEnergyActive
epc8221RevEnergyReactive
epc8221RevEnergyActiveResetta
ble
epc8221RevEnergyReactiveResett
able
epc8221LineSensorName
epc8221OVPIndex
epc8221OVPStatus
epc8221Pw rSupplyIndex
epc8221Pw rSupplyStatus
epc8221NTPTimeValid
epc8221NTPUnixTime
epc8221NTPLastValidTimestamp
epc8221SensorIndex
epc8221TempSensor
epc8221HygroSensor
epc8221InputSensor
epc8221AirPressure
epc8221Dew Point
epc8221Dew PointDiff
epc8221ExtSensorName
4.6.2
Geräte MIB 8226
Es folgt eine Tabelle aller gerätespezifischen OID's die über SNMP angesprochen wer-
den können. Bei der numerischen OID Darstellung wurde der Präfix "1.3.6.1.4.1.28507"
zur Gude Enterprise OID aus Platzgründen bei jedem Eintrag in der Tabelle weggelas-
65
Expert Power Control 8221/8226
Resettable Absolute Reactive Energy counter.
.56.1.5.1.2.1.15.x
Time in seconds since last Energy Counter reset.
.56.1.5.1.2.1.16.x
Forw ard Active Energy counter.
.56.1.5.1.2.1.17.x
Forw ard Reactive Energy counter.
.56.1.5.1.2.1.18.x
Resettable Forw ard Active Energy counter.
.56.1.5.1.2.1.19.x
Resettable Forw ard Reactive Energy counter.
.56.1.5.1.2.1.20.x
Reverse Active Energy counter.
.56.1.5.1.2.1.21.x
Reverse Reactive Energy counter.
.56.1.5.1.2.1.22.x
Resettable Reverse Active Energy counter.
.56.1.5.1.2.1.23.x
Resettable Reverse Reactive Energy counter.
.56.1.5.1.2.1.100.x
A textual string containing name of a Line Sensor
.56.1.5.2.1.1.x
None
.56.1.5.2.1.2.x
show s the status of the built-in Overvoltage Protection
.56.1.5.13.1.1.x
Index of Pow er Supply entries
.56.1.5.13.1.2.x
show s status of the Pow er Supply for each bank
.56.1.5.15.1.0
Show if valid Time is received
.56.1.5.15.2.0
show received NTP time as unixtime (secs since 1 January 1970)
.56.1.5.15.3.0
show seconds since last valid NTP timestamp received
.56.1.6.1.1.1.x
None
.56.1.6.1.1.2.x
actual temperature
.56.1.6.1.1.3.x
actual humidity
.56.1.6.1.1.4.x
logical state of input sensor
.56.1.6.1.1.5.x
actual air pressure
.56.1.6.1.1.6.x
dew point for actual temperature and humidity
.56.1.6.1.1.7.x
difference betw een dew point and actual temperature (Temp -
Dew Point)
.56.1.6.1.1.32.x
A textual string containing name of a external Sensor
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
OCTETS
RW
Integer32
RO
INTEGER
RO
Integer32
RO
INTEGER
RO
INTEGER
RO
Unsigned32
RO
Unsigned32
RO
Integer32
RO
Integer32
RO
Integer32
RO
INTEGER
RO
Integer32
RO
Integer32
RO
Integer32
RO
OCTETS
RW