OPERATION

Before operating the device for the first time after proper installation, please
connect the hood to the mains (please observe the generally valid safety
instructions).
Control panel keys
Fan
Fan
Fan
Light
On/Off

TROUBLESHOOTING

Fehler
Mögliche Ursache
Light on, but
The leaf blocked.
motor does not
The capacitor damaged.
work.
The motor jammed bearing
damaged.
The internal with of motor
off or a bad smell from the
motor.
Light does not
Light damaged.
work, motor
Power cord looses.
does not work.
Insufficient
The distance between the
suction.
body and the gas top too
long.
Too much ventilation from
open doors or windows.
Low level
Medium level
Highest level
Switching the lighting on and off.
Off switch
Lösung
Get rid of the blocking.
Replace capacitor.
Replace motor.
Replace motor.
Replace lights.
Connect the wires as per the
electric diagram.
Readjust the distance.
Choose a new place and
resemble the machine.