Herunterladen Inhalt Inhalt Diese Seite drucken

Villeroy & Boch ProDetect 2 Bedienungsanleitung Seite 75

Urinalspülsystem
Vorschau ausblenden Andere Handbücher für ProDetect 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fault diagnosis
Fault
Water discharge has
been detected
S. 75
Possible cause
Hoses are leaking
Fault rectification
Make sure that the connection spi-
got has been pushed into the water
connection adequately and is pro-
perly sealed.
Make sure that the seals and the
sieve seal on the inlet and outlet
of the solenoid valve have been
mounted in the correct position.
Make sure that the two union nuts
on the inlet and outlet of the so-
lenoid valve are tightened adequa-
tely and properly.
Make sure that the hose connec-
tions are screwed into the connec-
tion spigot adequately.
Make sure that the seal ring on the
connection spigot is fitted correct-
ly.