Fault diagnosis

18 Fault diagnosis

18.1 Fault rectification

Fault
Urinal not flushing
S. 71
Possible cause
No power supply
No water supply
Fault rectification
Make sure that the battery com-
partment / power supply unit is
connected to the controller.
Check the connection between the
power supply unit and the dome-
stic power connection.
Check cable connection.
Check battery (diagnostics mode,
see "Diagnosis & user statistics",
page
67).
Open the stop cock on the water
supply line.
Make sure that the solenoid valve
is connected to the controller.
Check the functioning of the so-
lenoid valve (diagnostics mode,
see "Diagnosis & user statistics",
page 67
or check via app).