Fixing To Concrete Plinth; Fixing To Miele Plinth; Options/Accessories; Miele Plinth (Optional Accessory Available To Purchase Separately) - Miele PDR 918 EL Installationsplan

Elektrobeheizt gewerbliche trockner
Inhaltsverzeichnis

Werbung

en - Technical data

Fixing to concrete plinth

Tensioning strips
Wood screws DIN 571 (Ø × length)
Plugs (Ø × length)
If the tumble dryer is being fixed to a concrete plinth on site, fixing in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.
Fixing to Miele plinth
Tensioning strips
Wood screws DIN 571 (Ø × length)
Plugs (Ø × length)
If the tumble dryer is being fixed to a Miele plinth (optional accessory available to purchase separately), fixing in place is absolutely es-
sential.
Fastenings for floating screed must be supplied by the customer on site.

Options/Accessories

Miele plinth (optional accessory available to purchase separately)
Width
Height
Depth

Concrete base (on site)

Minimum width
Recommended height
Minimum height
Minimum depth
The quality of the concrete and its strength must be assessed according to the machine load. The on-site concrete plinth must be fixed
adequately to the floor.
22
Quantity
2
2
2
Quantity
4
4
4
Screw size
6×40 mm
10×50 mm
Screw size
8×65 mm
12×60 mm
900 mm
127 mm
868 mm
900 mm
100 mm
50 mm
1100 mm