Herunterladen Inhalt Inhalt Diese Seite drucken

STEPCRAFT D-Serie Betriebsanleitung Seite 49

Vorschau ausblenden Andere Handbücher für D-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Property
Driving direction
Reference switch at the end (X-axis)
Reference switch at the end (Y-axis)
Reference switch at the end (Z-axis)
Order of reference drive
Soft Limit X-axis
Soft Limit Y-axis
Soft Limit Z-axis
Reference position X
Reference position Y
Reference position Z
* The effectively usable Y-travel distance can be reduced by around 1-2 mm, depending on the software configuration.
** The travel distance of the Z-axis is reduced for constructional reasons. This applies to the areas around the X-positions
from X = 0 to 35 mm and X = "max. travel distance - 35 mm" to "max. travel distance". The travel distance is reduced
by around 10 mm. These circumstances are shown in the image below.
STEPCRAFT D.300
STEPCRAFT D.420
Depending on control software used
0 – 207 mm
0 – 297 mm
0 – 297 mm
0 – 417 mm
0 – 104 mm
0 – 137 mm
297 mm
47
STEPCRAFT D.600
Negative
Positive
Negative
Z −> X −> Y
0 – 417 mm
0 – 597 mm
0 – 137 mm
0 mm
417 mm
597 mm
0 mm
STEPCRAFT D.840
0 – 597 mm
0 – 837 mm
0 – 137 mm
837 mm

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für STEPCRAFT D-Serie

Diese Anleitung auch für:

D.300D.420D.600D.840