Attention! The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
31642000/31643000: The flow is changed from
bath to shower function by pulling the knop at the
upper side of the spout. After shutting off the water
flow, the mixer returns automatically to the bath
function.

Technical Data

Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1⁄2:
Rate of flow 0,3 MPa:
anti-pollution function
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work - Flow limiter in handshower isn't
6
English
max. 1 MPa
1,6 MPa
max. 80° C
65° C
150 ± 16 mm
cold right - hot left
approx. 17 l/min
Cause
- Shower filter seal dirty
- Non return valve didn't move
back
- Cartridge defective,calcified
- Cartridge defective
- Hot water limiter incorrectly set
removed
- Filter are dirty
- Non return valve didn't move
back
To adjust the hot water limiter on single lever mix-
ers, please see page 23.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
0,15 MPa.
Attention!
The non return valves must be checked once a
year.
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
escutcheon
6
S - unions
7
aerator cpl.
8
selector
9
diverter knob
10 non return valve
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Kartusche austauschen
- Kartusche austauschen
- Warmwasserbegrenzung einstel-
len
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves
31692000
96338000
97406000
97977000
92730000
94135000
94140000
13956000
97978000
97981000
97980000

Werbung