Assembly instructions

Electrical connection

• The electrical connection must be carried out by a
qualified electrician who is authorised to carry out such
work!
• Statutory regulations and the connection specifications issued
by the local power supply company must be strictly observed.
• When connecting the appliance it must be ensured that there
is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3 mm. Line-protecting switches, fuses or contactors are
suitable cut-out devices. When connecting and repairing the
appliance disconnect it from the electricity supply with one of
these devices.
• The earth wire must be sufficiently long so that if the strain
relief fails, the live wires of the connecting cable are subjected
to tension before the earth wire.
• Any superfluous cable must be removed from the installation
area beneath the appliance.
• Make sure that the local mains voltage is the same as the
voltage on the rating label.
• The hob has been fitted with a temperature-resistant
connection cable in the factory.
• The connection cable must be at least H05 RR-F.
• If the excess cable of this appliance is damaged, it has to be
replaced by the manufacturer, the Customer Service of the
manufacturer or by another qualified person to avoid danger.
• Full protection against accidental contact must be ensured on
installation.
• Attention: Incorrect connection may result in the power
electronics unit being destroyed.
Power supply
Mains voltage: 220 - 240V~, 50-60 Hz
Component rated voltage: 220 - 240V
32

Start of operation

Immediately after voltage has been applied (connection to the
mains), the sensor keys will be calibrated.
This will take approx. 5 seconds.
During calibration the sensor keys are set according to the level
of brightness of the surroundings.
This is why no sensor keys may be touched during this
process and no objects may be placed on the sensor keys!
5 Sek.
How to remedy faulty calibration:
The hob will need to be disconnected from the power supply for
at least 10 seconds and will then need to be re-connected.
Important: the sensor keys must remain unused!
Important
Inspection (quality control) of the hob during production
may result in information still being contained in the
memory. This could mean that an H lights up in the cooking
level display for a maximum of 60 minutes once the
appliance has been connected to the mains power supply.
This is of no significance to the user.