Scope of delivery
The scope of delivery includes:
• 1 sauna heater
• 1 Installation and operation manual
Technical Data
Power supply
Power output
Suitable for sauna cabin size
Min. size air inlet and air outlet
Weight, excl. stones / packaging
Dimensions H x W x D
Stone fillung
Power extension required (LSG unit)
Suitable sauna control units
Leakage current
Intended use
Fuse protection for control unit
Fuse protection for power extension
Connection mains - control unit
Connection mains - power extension
Connection control unit - heater
Connection power extension - heater
Connection control unit - power extension
All cross sections of a line are minimum diameters in mm² (Copper line)
15 kW
18 kW
21 kW
18 - 25 m³
24 - 30 m³
24 - 34 m³
50 x 6 cm
48 kg
49 kg
50 kg
95 x 75 x 53 cm
30 kg (stones not inlcuded)
EmoTec LSG 09R
EOS Econ series, Compact series, EmoTec series,
max. 0,75 mA per kW heating power
Sauna heater for operation in commecial saunas
3 x 16 A
5 x 2,5 mm²
5 x 2,5 mm²
5 x 1,5 mm²
5 x 1,5 mm²
EN
400 V 3N AC 50 Hz
24 kW
27 kW
35 - 40 m³
40 - 50 m³
50 x 8 cm
50 x 9 cm
61,5 kg
62,5 kg
95 x 100 x 53 cm
45 kg (stones not inlcuded)
LSG 18
EmoStyle series, EmoTouch series
3 x 16 A
3 x 35 A
5 x 6 mm²
5 x 6 mm²
4 x 1,5 mm²
30 kW
36 kW
50 - 65 m³
65 - 75 m³
50 x 10 cm
50 x 10 cm
63,5 kg
65,5 kg
LSG 36
3 x 50 A
3 x 63 A
3 x 1,5 mm²
5 x 10 mm² 5 x 16 mm²
2 St. 5 x 6
2 St. 5 x 6
mm²
mm²
23